Title: Detailed Investigation of Three-Dimensional Modeling and Printing Technologies From Medical Images To Analyze Femoral Head Fractures Using Finite Element Analysis
Authors: Çıklacandır, Samet
Mihçin, Şenay
İşler, Yalçın
Keywords: Educational tools
Femoral head
Finite element analysis
Radiological images
Publisher: Elsevier
Abstract: Objectives: One of the fields, where additive manufacturing has numerous applications, is biomedical engineering. 3D printing is preferred over traditional manufacturing methodologies, mostly while developing subject-specific implants and medical devices. This study aims to provide a process flow detailing all the stages starting from the acquisition of radiological images from different imaging modalities; such as computed tomography (CT) and magnetic resonance imaging (MRI) to the printing of the bone morphology and finite element analysis; including the validation process. Materials & Methods: First, the CT scan of a lower abdomen area of a patient was converted into a 3D image using interactive medical imaging control system software. The segmentation process was applied to isolate the femoral head from the soft tissue and the pelvic bone. After the roughness errors and the gaps in the segments were removed using the 3Matic software, the file was converted to stereolithography (STL) file format to transfer to the 3D printer. The printing process was carried out via commercial powder-based Selective Laser Sintering (SLS) printer. The subject-specific femoral head model was formed in 3D. The Finite Element Analysis (FEA) of the femoral head was performed using a commercial FE software package. Results: The results show that experimental analysis and the CT scan-based FEA were compatible both for the stress distributions and the strain values as predicted by the models (R2=0.99). The deviation was calculated as approximately 12% between the experimental results and the Finite Element (FE) results. In addition, it was observed that the SLS technique produced useful results for modeling biomedical tissues with about 24x faster prototyping time. Conclusion: The prescribed process flow could be utilized in clinical settings for the pre-planning of the surgeries (≈428 minutes for femoral head) and also as an educational tool in the biomedical engineering field.
URI: https://doi.org/10.1016/j.irbm.2022.04.005
https://hdl.handle.net/11147/12224
ISSN: 1959-0318
Appears in Collections:Mechanical Engineering / Makina Mühendisliği
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Files in This Item:
File Description SizeFormat 
1-s2.0-S1959031822000379-main.pdf
  Until 2025-07-01
Article2.37 MBAdobe PDFView/Open    Request a copy
Show full item record



CORE Recommender

SCOPUSTM   
Citations

4
checked on Dec 13, 2024

WEB OF SCIENCETM
Citations

3
checked on Dec 7, 2024

Page view(s)

1,792
checked on Dec 16, 2024

Download(s)

4
checked on Dec 16, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.