Please use this identifier to cite or link to this item:
https://hdl.handle.net/11147/11254
Title: | Parametric Analysis for the Design of Hip Joint Replacement Simulators | Authors: | Torabnia, Shams Mihçin, Şenay Lazoğlu, İsmail |
Keywords: | In vitro Parametric design Simulator Total hip replacement |
Publisher: | IEEE | Abstract: | The simulation of wear, between the components of artificial hip joint implants, is a complicated problem that does not have a robust analytical answer yet. Many studies have been conducted to predict the wear between the femur head and the acetabular cup, as the debris generated due to the wear might produce adverse effects after the surgery. Hip joint simulators provide a means to quantify the amount of wear in preclinical settings, as an in vitro method. However, this brings some other challenges in terms of bio-fidelity. The simulators use force and range of motion data as input and provide wear information as an output. For this reason, it is important to be able to simulate the realistic conditions, by the proper transmission of force and position controlling of the components. Many studies performed on wear simulators but none of them worked on the machine parameters such as power consumption and sensitivity to external inputs in detail. In this study, we perform a sensitivity analysis of the factors affecting the forces acting on the femur head. In silico simulations were performed by changing the values of acting force, friction coefficient, and radius of femur head to understand the effects of each parameter on the frictional moment of the joint. These analyses demonstrate the importance of using correct parameters while designing simulators, which accept flexible boundary conditions. The architecture of the hip simulator was also investigated for the first time. The results are expected to pave the way for improving the bio-fidelity of the simulators in the field of biomechanics. © 2021 IEEE. | Description: | 2021 IEEE International Symposium on Medical Measurements and Applications, MeMeA 2021 -- 23 June 2021 through 25 June 2021 | URI: | http://doi.org/10.1109/MeMeA52024.2021.9478689 https://hdl.handle.net/11147/11254 |
ISBN: | 9781665419147 |
Appears in Collections: | Mechanical Engineering / Makina Mühendisliği Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Files in This Item:
File | Size | Format | |
---|---|---|---|
Parametric_analysis.pdf | 2.85 MB | Adobe PDF | View/Open |
CORE Recommender
SCOPUSTM
Citations
2
checked on Dec 20, 2024
WEB OF SCIENCETM
Citations
1
checked on Nov 23, 2024
Page view(s)
320
checked on Dec 16, 2024
Download(s)
240
checked on Dec 16, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.