Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/11251
Full metadata record
DC FieldValueLanguage
dc.contributor.authorÇelik, Emre-
dc.contributor.authorAlemdar, Furkan-
dc.contributor.authorBatı, Murat-
dc.contributor.authorDaşdemir, Muhammed Furkan-
dc.contributor.authorBüyükbayraktar, Onur Alp-
dc.contributor.authorChethan, K.N.-
dc.contributor.authorMihçin, Şenay-
dc.date.accessioned2021-11-06T09:27:12Z-
dc.date.available2021-11-06T09:27:12Z-
dc.date.issued2022-
dc.identifier.isbn9783030862961-
dc.identifier.issn2367-3370-
dc.identifier.urihttp://doi.org/10.1007/978-3-030-86297-8_2-
dc.identifier.urihttps://hdl.handle.net/11147/11251-
dc.descriptionInternational Conference of the Polish Society of Biomechanics, BIOMECHANICS 2020 -- 8 September 2021 through 10 September 2021en_US
dc.description.abstractPolylactic acid (PLA) is a biodegradable non-toxic, biocompatible polymer used as a popular filament material in biomedical applications with the advance of 3D printing technologies. PLA is considered a suitable implant material due to its contribution to bone regeneration. In this study, the use of PLA in Total Hip Arthroplasty (THA) as a liner material was assessed. In this regard, the PLA liner with different material combinations in THA was examined to provide evidence for its potential. The hip implant prototypewas drawn using a computer-aided design tool then transferred into a commercial finite element analysis (FEA) software. The prototypesconsisted of assemblies of PLA with titanium, chrome cobalt, stainless steels, dense NiTi shape-alloys, and Alumina-Zirconia. Simulations were run under static loading conditions. To evaluate and compare the results for the optimum design; factor of safety, total deformation and von Mises stress analysis were used. The results show that Co-Cr implemented implants produce the highest factor of safety. When Al-Zi combined with PLA, it produced least deformation and reasonable von- Mises stress values. PLA might perform best when used with Al-Zi. As a next step, experimental pre-clinical tests are planned to assess the clinical potential. © 2022, The Author(s), under exclusive license to Springer Nature Switzerland AG.en_US
dc.description.sponsorshipFunding. This research was funded by TUBITAK 2232 International Outstanding Researchers Funding Scheme with Grant No of 118C188 ‘New Generation Implants for All’ project.en_US
dc.language.isoenen_US
dc.publisherSpringeren_US
dc.relation.ispartofLecture Notes in Networks and Systemsen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBiomaterialen_US
dc.subjectFEAen_US
dc.subjectPLAen_US
dc.subjectPlastic lineren_US
dc.subjectTotal Hip Arthroplastyen_US
dc.titleMechanical investigation for the use of polylactic acid in Total Hip Arthroplasty using FEM analysisen_US
dc.typeConference Objecten_US
dc.departmentİzmir Institute of Technology. Mechanical Engineeringen_US
dc.identifier.volume328 LNNSen_US
dc.identifier.startpage17en_US
dc.identifier.endpage23en_US
dc.identifier.scopus2-s2.0-85115217301en_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1007/978-3-030-86297-8_2-
dc.identifier.wosqualityN/A-
dc.identifier.scopusqualityQ4-
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeConference Object-
crisitem.author.dept03.10. Department of Mechanical Engineering-
Appears in Collections:Mechanical Engineering / Makina Mühendisliği
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

6
checked on Nov 15, 2024

Page view(s)

212
checked on Nov 18, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.