Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/10162
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBarış, Mustafa-
dc.contributor.authorSerinan, Efe-
dc.contributor.authorÇalışır, Meryem-
dc.contributor.authorŞimşek, Kürşat-
dc.contributor.authorAktaş, Safiye-
dc.contributor.authorYılmaz, Osman-
dc.contributor.authorSeçil, Mustafa-
dc.contributor.authorKılıç Özdemir, Sevgi-
dc.date.accessioned2021-01-24T18:32:39Z-
dc.date.available2021-01-24T18:32:39Z-
dc.date.issued2020-
dc.identifier.issn2458-8938-
dc.identifier.issn2564-7288-
dc.identifier.urihttps://doi.org/10.30621/jbachs.2020.902-
dc.identifier.urihttps://hdl.handle.net/11147/10162-
dc.identifier.urihttps://search.trdizin.gov.tr/yayin/detay/370778-
dc.description.abstractObjectives: Volume measurement of subcutaneous xenograft tumors in nude mice models is an important metric to assess tumor growth or response to therapy. Manual calipers are widely used for this purpose. But the measurements with manual calipers may be inaccurate. Contrarily, three-dimensional (3D) ultrasonographic measurements give reliable and accurate tumor volume calculation. We aim to; evaluate the accuracy of common four formulas given in the literature to estimate xenograft tumor volumes based on manual caliper measurements and offer a new coefficient for a better estimation of the tumor volumes. Patients and Methods: Detailed manual diameter measurements of xenograft tumors were in 14 nude mice performed using Vernier caliper. Tumor volumes were calculated using the suggested formulas in the literature based on manual measurements. 3D ultrasound volume measurements were performed on same xenograft tumors using high resolution Vevo 2100 imaging system. To propose a new coefficient; means of ratio between manual and ultrasound volume measurement values were used. Also, data set was divided into two subgroups as tumor volume under 800 mm3 and over 800 mm3. New coefficients for each subgroup were defined. Results: Only with prolate ellipsoid formula there was no statistically significant difference between volume measurements with two methods (p=0,24). Our proposed formula (0,45 L*W*H) could estimate tumor volumes as good as prolate ellipsoid formula. Coefficient 0,35 and 0,81 in the same formula were found efficient in the selected subgroups. Conclusion: Using one common coefficient/formula for tumor volume estimation in any tumor size can be inaccurate. Appropriate coefficient should be chosen according to the dataset worked with.en_US
dc.language.isoenen_US
dc.publisherDokuz Eylül Üniversitesi-
dc.relation.ispartofJournal of Basic and Clinical Health Sciencesen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleXenograft tumor volume measurement in nude mice: Estimation of 3D ultrasound volume measurements based on manual caliper measurementsen_US
dc.typeArticleen_US
dc.institutionauthorÖzdemir, Sevgi Kılıç-
dc.departmentİzmir Institute of Technology. Chemical Engineeringen_US
dc.identifier.volume4en_US
dc.identifier.issue2en_US
dc.identifier.startpage90en_US
dc.identifier.endpage95-
dc.identifier.wosWOS:000533600300001en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.30621/jbachs.2020.902-
dc.relation.doi10.30621/jbachs.2020.902en_US
dc.coverage.doi10.30621/jbachs.2020.902en_US
dc.identifier.trdizinid370778en_US
dc.identifier.scopusqualityN/A-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.grantfulltextopen-
item.cerifentitytypePublications-
item.fulltextWith Fulltext-
item.openairetypeArticle-
item.languageiso639-1en-
crisitem.author.dept03.02. Department of Chemical Engineering-
Appears in Collections:Chemical Engineering / Kimya Mühendisliği
TR Dizin İndeksli Yayınlar / TR Dizin Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File SizeFormat 
10.30621-jbachs.2020.902-1460521.pdf2.37 MBAdobe PDFView/Open
Show simple item record



CORE Recommender

WEB OF SCIENCETM
Citations

7
checked on Nov 9, 2024

Page view(s)

9,980
checked on Nov 18, 2024

Download(s)

320
checked on Nov 18, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.