Bilgilendirme: Sürüm Güncellemesi ve versiyon yükseltmesi nedeniyle, geçici süreyle zaman zaman kesintiler yaşanabilir ve veri içeriğinde değişkenlikler gözlemlenebilir. Göstereceğiniz anlayış için teşekkür ederiz.
 

Arsenic Removal From Groundwater Using an Aerated Electrocoagulation Reactor With 3d Al Electrodes in the Presence of Anions

No Thumbnail Available

Date

2021

Authors

Gören, Ayşegül Yağmur

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier

Open Access Color

OpenAIRE Downloads

OpenAIRE Views

Research Projects

Journal Issue

Abstract

Co-occurrence of arsenic and anions in groundwater causes a severe health problems and combine effects of these pollutants significantly affect performance of treatment process. Thus, this study has been conducted to examine the combine effects of anions on arsenic removal using aerated electrocoagulation (EC) reactor with 3D Al electrodes in groundwater. A 3-level, six factors Box-Behnken experimental design (BBD) was applied to investigate the individual and combine effect of anions and operating time: phosphate (x1: 1–10 mg L?1), silica (x2: 20–80 mg L?1), bicarbonate (x3: 130–670 mg L?1), fluoride (x4: 2–10 mg L?1), boron (x5: 5–10 mg L?1), and operating time (x6: 8–22 min) on desired responses. The specified responses were effluent arsenic concentration (Cf,As), removal efficiency of arsenic (Re), consumptions of energy and electrode (ENC and ELC), operational cost (OC), and adsorption capacity (qe). The optimum operating parameters predicted using BBD were found to be x1: 1.0 mg L?1, x2: 26.0 mg L?1, x3: 651.5 mg L?1, x4: 2.0 mg L?1, x5: 9.9 mg L?1, and x6: 10.5 min considering highest removal efficiency of arsenic and lowest operational cost. Under these operating conditions, the experimental values of Cf,As, Re, ENC, ELC, OC, and qe were found to be 2.82 ?g L?1, 98.6%, 0.411 kWh m?3, 0.0124 kg m?3, 0.098 $ m?3, and 17.65 ?g As (mg Al)?1, respectively. Furthermore, mathematical modelling was conducted using quadratic regression model and response surface analysis was performed to understand the relationship between independent parameters and responses. © 2020 Elsevier Ltd

Description

Keywords

3D Al ball Electrodes, Aerated electrocoagulation, Anions, Arsenic removal, Groundwater

Turkish CoHE Thesis Center URL

Fields of Science

Citation

WoS Q

Q1

Scopus Q

Q1
OpenCitations Logo
OpenCitations Citation Count
54

Source

Chemosphere

Volume

263

Issue

Start Page

End Page

SCOPUS™ Citations

53

checked on Sep 22, 2025

Web of Science™ Citations

43

checked on Sep 22, 2025

Page Views

543

checked on Sep 22, 2025

Downloads

67

checked on Sep 22, 2025

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
7.0

Sustainable Development Goals

3

GOOD HEALTH AND WELL-BEING
GOOD HEALTH AND WELL-BEING Logo

6

CLEAN WATER AND SANITATION
CLEAN WATER AND SANITATION Logo

9

INDUSTRY, INNOVATION AND INFRASTRUCTURE
INDUSTRY, INNOVATION AND INFRASTRUCTURE Logo

11

SUSTAINABLE CITIES AND COMMUNITIES
SUSTAINABLE CITIES AND COMMUNITIES Logo