Bilgilendirme: Sürüm Güncellemesi ve versiyon yükseltmesi nedeniyle, geçici süreyle zaman zaman kesintiler yaşanabilir ve veri içeriğinde değişkenlikler gözlemlenebilir. Göstereceğiniz anlayış için teşekkür ederiz.
 

Ventilation Strategies for the Preventive Conservation of Manuscripts in the Necip Paşa Library, Izmir, Turkey

dc.contributor.author Coşkun, Turgay
dc.contributor.author Şahin, Cem Doğan
dc.contributor.author Gülhan, Özcan
dc.contributor.author Durmuş Arsan, Zeynep
dc.contributor.author Gökçen Akkurt, Gülden
dc.contributor.other 02.02. Department of Architecture
dc.contributor.other 03.10. Department of Mechanical Engineering
dc.contributor.other 01. Izmir Institute of Technology
dc.contributor.other 03.06. Department of Energy Systems Engineering
dc.contributor.other 03. Faculty of Engineering
dc.contributor.other 02. Faculty of Architecture
dc.coverage.doi 10.1016/B978-0-12-813734-5.00011-1
dc.date.accessioned 2020-07-18T03:35:20Z
dc.date.available 2020-07-18T03:35:20Z
dc.date.issued 2018
dc.description.abstract Libraries are specific spaces in which the indoor microclimate should meet rigorous requirements such as the thermal comfort of humans and the conservation of books, manuscripts, and cultural property. An inadequate indoor microclimate (mainly temperature, relative humidity, and their fluctuations) in libraries may cause chemical, biological, and mechanical degradations in paper-based collections. In this chapter, the indoor microclimate of the Necip Paşa Library, the historic library located in Tire-Izmir, Turkey, is discussed from the perspective of the preventive conservation of manuscripts. The library, which has no active heating, cooling, and ventilation system, was modeled with the help of a building energy simulation tool, DesignBuilder. The indoor temperature and relative humidity were monitored throughout 1 year and the model was calibrated with respect to these measurements. To reduce the risks of the manuscripts degrading, ventilation strategies were proposed including natural and mechanical control. The results showed that risks of chemical degradation can be diminished to some extent. © 2018 Elsevier Inc. All rights reserved. en_US
dc.identifier.doi 10.1016/B978-0-12-813734-5.00011-1 en_US
dc.identifier.isbn 9780128137352
dc.identifier.scopus 2-s2.0-85041255600
dc.identifier.uri https://doi.org/10.1016/B978-0-12-813734-5.00011-1
dc.identifier.uri https://hdl.handle.net/11147/7890
dc.language.iso en en_US
dc.publisher Elsevier en_US
dc.relation.ispartof Exergetic, Energetic and Environmental Dimensions en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Dynamic simulation en_US
dc.subject Historic library en_US
dc.subject Indoor microclimate en_US
dc.subject Preventive conservation of manuscripts en_US
dc.subject Ventilation strategy en_US
dc.title Ventilation Strategies for the Preventive Conservation of Manuscripts in the Necip Paşa Library, Izmir, Turkey en_US
dc.type Book Part en_US
dspace.entity.type Publication
gdc.author.institutional Coşkun, Turgay
gdc.author.institutional Gökçen Akkurt, Gülden
gdc.author.institutional Gülhan, Özcan
gdc.author.institutional Coşkun, Turgay
gdc.author.institutional Gökçen Akkurt, Gülden
gdc.author.institutional Durmuş Arsan, Zeynep
gdc.author.institutional Şahin, Cem Doğan
gdc.coar.access open access
gdc.coar.type text::book::book part
gdc.description.department İzmir Institute of Technology. Energy Systems Engineering en_US
gdc.description.department İzmir Institute of Technology. Architecture en_US
gdc.description.endpage 192 en_US
gdc.description.publicationcategory Kitap Bölümü - Uluslararası en_US
gdc.description.scopusquality N/A
gdc.description.startpage 179 en_US
gdc.description.wosquality N/A
gdc.identifier.openalex W2761449709
gdc.openalex.fwci 2.511
gdc.openalex.normalizedpercentile 0.79
gdc.opencitations.count 0
gdc.scopus.citedcount 2
local.message.claim 2022-06-08T11:42:41.843+0300 *
local.message.claim |rp00741 *
local.message.claim |submit_approve *
local.message.claim |dc_contributor_author *
local.message.claim |None *
relation.isAuthorOfPublication d605b2bf-7a5c-4ce9-bf36-ce1edee16d36
relation.isAuthorOfPublication 9b15b3a3-c6fe-40fe-8773-455b311ee7bd
relation.isAuthorOfPublication 401fccd6-20bd-41d0-9539-3dd159bbf105
relation.isAuthorOfPublication d2027f24-5e14-49c9-bfb0-677b556483c8
relation.isAuthorOfPublication.latestForDiscovery d605b2bf-7a5c-4ce9-bf36-ce1edee16d36
relation.isOrgUnitOfPublication 9af2b05f-28ac-4026-8abe-a4dfe192da5e
relation.isOrgUnitOfPublication 9af2b05f-28ac-4022-8abe-a4dfe192da5e
relation.isOrgUnitOfPublication 9af2b05f-28ac-4003-8abe-a4dfe192da5e
relation.isOrgUnitOfPublication 9af2b05f-28ac-4017-8abe-a4dfe192da5e
relation.isOrgUnitOfPublication 9af2b05f-28ac-4004-8abe-a4dfe192da5e
relation.isOrgUnitOfPublication 9af2b05f-28ac-4006-8abe-a4dfe194da5e
relation.isOrgUnitOfPublication.latestForDiscovery 9af2b05f-28ac-4026-8abe-a4dfe192da5e

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
10.1016@B978-0-12-813734-5.00011-1.pdf
Size:
541.15 KB
Format:
Adobe Portable Document Format