Ventilation Strategies for the Preventive Conservation of Manuscripts in the Necip Paşa Library, Izmir, Turkey
dc.contributor.author | Coşkun, Turgay | |
dc.contributor.author | Şahin, Cem Doğan | |
dc.contributor.author | Gülhan, Özcan | |
dc.contributor.author | Durmuş Arsan, Zeynep | |
dc.contributor.author | Gökçen Akkurt, Gülden | |
dc.contributor.other | 02.02. Department of Architecture | |
dc.contributor.other | 03.10. Department of Mechanical Engineering | |
dc.contributor.other | 01. Izmir Institute of Technology | |
dc.contributor.other | 03.06. Department of Energy Systems Engineering | |
dc.contributor.other | 03. Faculty of Engineering | |
dc.contributor.other | 02. Faculty of Architecture | |
dc.coverage.doi | 10.1016/B978-0-12-813734-5.00011-1 | |
dc.date.accessioned | 2020-07-18T03:35:20Z | |
dc.date.available | 2020-07-18T03:35:20Z | |
dc.date.issued | 2018 | |
dc.description.abstract | Libraries are specific spaces in which the indoor microclimate should meet rigorous requirements such as the thermal comfort of humans and the conservation of books, manuscripts, and cultural property. An inadequate indoor microclimate (mainly temperature, relative humidity, and their fluctuations) in libraries may cause chemical, biological, and mechanical degradations in paper-based collections. In this chapter, the indoor microclimate of the Necip Paşa Library, the historic library located in Tire-Izmir, Turkey, is discussed from the perspective of the preventive conservation of manuscripts. The library, which has no active heating, cooling, and ventilation system, was modeled with the help of a building energy simulation tool, DesignBuilder. The indoor temperature and relative humidity were monitored throughout 1 year and the model was calibrated with respect to these measurements. To reduce the risks of the manuscripts degrading, ventilation strategies were proposed including natural and mechanical control. The results showed that risks of chemical degradation can be diminished to some extent. © 2018 Elsevier Inc. All rights reserved. | en_US |
dc.identifier.doi | 10.1016/B978-0-12-813734-5.00011-1 | en_US |
dc.identifier.isbn | 9780128137352 | |
dc.identifier.scopus | 2-s2.0-85041255600 | |
dc.identifier.uri | https://doi.org/10.1016/B978-0-12-813734-5.00011-1 | |
dc.identifier.uri | https://hdl.handle.net/11147/7890 | |
dc.language.iso | en | en_US |
dc.publisher | Elsevier | en_US |
dc.relation.ispartof | Exergetic, Energetic and Environmental Dimensions | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Dynamic simulation | en_US |
dc.subject | Historic library | en_US |
dc.subject | Indoor microclimate | en_US |
dc.subject | Preventive conservation of manuscripts | en_US |
dc.subject | Ventilation strategy | en_US |
dc.title | Ventilation Strategies for the Preventive Conservation of Manuscripts in the Necip Paşa Library, Izmir, Turkey | en_US |
dc.type | Book Part | en_US |
dspace.entity.type | Publication | |
gdc.author.institutional | Coşkun, Turgay | |
gdc.author.institutional | Gökçen Akkurt, Gülden | |
gdc.author.institutional | Gülhan, Özcan | |
gdc.author.institutional | Coşkun, Turgay | |
gdc.author.institutional | Gökçen Akkurt, Gülden | |
gdc.author.institutional | Durmuş Arsan, Zeynep | |
gdc.author.institutional | Şahin, Cem Doğan | |
gdc.coar.access | open access | |
gdc.coar.type | text::book::book part | |
gdc.description.department | İzmir Institute of Technology. Energy Systems Engineering | en_US |
gdc.description.department | İzmir Institute of Technology. Architecture | en_US |
gdc.description.endpage | 192 | en_US |
gdc.description.publicationcategory | Kitap Bölümü - Uluslararası | en_US |
gdc.description.scopusquality | N/A | |
gdc.description.startpage | 179 | en_US |
gdc.description.wosquality | N/A | |
gdc.identifier.openalex | W2761449709 | |
gdc.openalex.fwci | 2.511 | |
gdc.openalex.normalizedpercentile | 0.79 | |
gdc.opencitations.count | 0 | |
gdc.scopus.citedcount | 2 | |
local.message.claim | 2022-06-08T11:42:41.843+0300 | * |
local.message.claim | |rp00741 | * |
local.message.claim | |submit_approve | * |
local.message.claim | |dc_contributor_author | * |
local.message.claim | |None | * |
relation.isAuthorOfPublication | d605b2bf-7a5c-4ce9-bf36-ce1edee16d36 | |
relation.isAuthorOfPublication | 9b15b3a3-c6fe-40fe-8773-455b311ee7bd | |
relation.isAuthorOfPublication | 401fccd6-20bd-41d0-9539-3dd159bbf105 | |
relation.isAuthorOfPublication | d2027f24-5e14-49c9-bfb0-677b556483c8 | |
relation.isAuthorOfPublication.latestForDiscovery | d605b2bf-7a5c-4ce9-bf36-ce1edee16d36 | |
relation.isOrgUnitOfPublication | 9af2b05f-28ac-4026-8abe-a4dfe192da5e | |
relation.isOrgUnitOfPublication | 9af2b05f-28ac-4022-8abe-a4dfe192da5e | |
relation.isOrgUnitOfPublication | 9af2b05f-28ac-4003-8abe-a4dfe192da5e | |
relation.isOrgUnitOfPublication | 9af2b05f-28ac-4017-8abe-a4dfe192da5e | |
relation.isOrgUnitOfPublication | 9af2b05f-28ac-4004-8abe-a4dfe192da5e | |
relation.isOrgUnitOfPublication | 9af2b05f-28ac-4006-8abe-a4dfe194da5e | |
relation.isOrgUnitOfPublication.latestForDiscovery | 9af2b05f-28ac-4026-8abe-a4dfe192da5e |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- 10.1016@B978-0-12-813734-5.00011-1.pdf
- Size:
- 541.15 KB
- Format:
- Adobe Portable Document Format