Architecture / Mimarlık
Permanent URI for this collectionhttps://hdl.handle.net/11147/24
Browse
Browsing Architecture / Mimarlık by Author "03. Faculty of Engineering"
Now showing 1 - 20 of 38
- Results Per Page
- Sort Options
Article Citation - WoS: 11Citation - Scopus: 11Adapting Cities To Pluvial Flooding: the Case of Izmir (türkiye)(MDPI, 2022-12) Salata, Stefano; Couch, Virginia Thompson; Velibeyoğlu, Koray; Baba, Alper; Saygın, Nicel; Uzelli, Taygun; 02.03. Department of City and Regional Planning; 03.03. Department of Civil Engineering; 02.02. Department of Architecture; 01.01. Units Affiliated to the Rectorate; 01. Izmir Institute of Technology; 03. Faculty of Engineering; 02. Faculty of ArchitectureIn the coming decades, climate change will be one of the most significant challenges for urban areas. The quantity, duration and intensity of events, such as flash rains and heat waves, will increase the vulnerability of urban regions while exposing citizens to potentially dangerous conditions. According to the current literature, mainstreaming resilience in urban planning means designing rules that strengthen urban systems’ adaptive and self-regulating functions by reducing their vulnerability. In this work, we aimed to build knowledge for the application of the sponge district concept to Izmir (Türkiye), one of Europe’s most vulnerable areas to pluvial flooding. To do this, we first analyzed the runoff in each urban sub-watershed, then employed a composite index to determine potential areas of intervention for nature-based solutions. Results show that 10% of Izmir’s urban areas are extremely vulnerable to cloudbursts, which means that 40% of the urban population is exposed to this phenomenon. Moreover, the runoff calculation in the sub-watershed demonstrated that the potential flood volume is underestimated, especially in the upslope areas. The results can be used as a template to suggest a stepwise approach to mainstream the resilience of densely-inhabited coastal urban catchments.Conference Object Citation - WoS: 20Citation - Scopus: 25Applying Underfloor Heating System for Improvement of Thermal Comfort in Historic Mosques: the Case Study of Salepçioglu Mosque, Izmir, Turkey(Elsevier Ltd., 2017) Bughrara, Khaled S. M.; Durmuş Arsan, Zeynep; Gökçen Akkurt, Gülden; 02.02. Department of Architecture; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureMosques differ from other types of buildings by having an intermittent operation schedule. Due to five prayer times per day throughout the year, mosques are fully or partially, yet periodically, occupied. This paper examines the potential of using an underfloor heating system for improvement of indoor thermal comfort in a historic mosque, which is naturally ventilated, heated and cooled, based on adaptive thermal comfort method. The selected Salepçioǧlu Mosque, housing valuable wall paintings, was built in 1905 in KemeraltI, Izmir, Turkey. It requires specific attention with its cultural heritage value. Firstly, indoor microclimate of the Mosque was monitored for one-year period of 2014-15. Then, dynamic simulation modelling tool, DesignBuilder v.4.2 was used to create the physical model of the Mosque. The ASHRAE Guideline 14 indices were utilized to calibrate the model, by comparing simulated and measured indoor air temperature to achieve hourly errors within defined ranges. The results of calibrated baseline model indicate that the Mosque does not satisfy acceptable thermal comfort levels for winter months that provided by the adaptive method. Then, the effect of underfloor heating was examined in the second model by the.Conference Object The Architectural Application of Altmann Linkage as a Light Shelf(Yaşar Üniversitesi, 2020) Atarer, Fulya; Kazanasmaz, Zehra Tuğçe; Korkmaz, Koray; Kiper, Gökhan; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 01. Izmir Institute of Technology; 03. Faculty of Engineering; 02. Faculty of ArchitectureDaylight and its penetration in a room are significant concerns in architectural design. Light shelves are necessary to control daylight on fenestration. In the literature, there are many daylight controller systems such as light shelves. This paper presents the possibility of using Altmann linkage as the basis of constructing such a light shelf in rectangular form. It is basically a horizontal or inclined device, having high reflectance on the upper surface to control and redistribute daylight, placed above the eye-level in the fenestration system. The performance of a light shelf varies according to its dimensions, distance to window sill, distance to window head, its rotation angle and orientation in terms of daylight efficiency and visual comfort. It is also used to provide shading. This system can be internal or external and being static or movable. A light shelf presents its maximum efficiency in south facing façades receiving higher direct sun incident angles in medium latitudes of northern hemisphere. The aim of this study is to explain the design process of an adaptable Altmann light shelf including dimensioning the links in a rectangular form, calculating rotation angles, modelling this device in Relux to test its daylight performance. Regarding the Altmann geometries, three variations are set while changing its distance to window sill. The aim is to test illuminance and uniformity. Relux calculates illuminance and uniformity at four significant dates and three chosen hours for each one, to obtain the best design.Article Art and Construction Related Qualities of 14th‒15th Century Monuments in a Rural Landscape on the Western Coast of Türkiye(KeAi Communications Co., 2024) Hamamcıoğlu Turan, Mine; Aktaş, Engin; Toköz, Özge Deniz; 02.02. Department of Architecture; 02.01. Department of Conservation and Restoration of Cultural Heritage; 03.03. Department of Civil Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureThis study aims to contribute to the understanding of the evolution of art and construction in the early settlements established by Turkish communities on the far west Asian coast by focusing on two developed examples in Urla Peninsula. Conventional surveying and evaluation techniques of architectural restoration and civil engineering were utilized. Key findings include the understanding of the hierarchy of rural settlements in the studied landscape: old Çesme the most developed village of peninsula in the 16th century. It was positioned along a valley in distance to coast, but in control of harbor that played significant role in commerce between Europe and Asia. Its mosque and tomb, dated to late 14th – early 15th centuries, used to crown it. Cylindrical minaret tower of mosque, domed tomb tower on a cubical base and squinch in the transition zone of mosque are evidences for Central Asian roots. Usage of local lime stone, re-usage of andesite blocks, framing of the stone blocks with bricks, and pendentive in tomb refer to Roman-Byzantine constructions. The study presents the development of Turkish art and construction on the far west Asian coast in the 14th‒15th centuries. Findings will be a guide for related conservation management in similar contexts. © 2024 The Author(s)Conference Object Citation - WoS: 2Citation - Scopus: 2A Case Study on the Selection of Optimum Loop Units for the Deployable Arch Structures Exposed To Lateral and Non-Uniform Gravity Loads(Elsevier, 2020) Yuceturk, K.; Aktas, E.; Maden, F.; Gur, S.; Mitropoulou, C. C.; 02.02. Department of Architecture; 03.03. Department of Civil Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureRadially deployable arches may be created by using various types of units. However, for any deployable structure to be constructed in real life, it should satisfy the structural regulations and codes. Despite various advantages from architectural perspective, deployable structures are weak to satisfy the operational code limits when compared to trusses with similar height and span. Therefore, weight minimization is very important to reduce the dead loads of the structure which facilitates the code-conformance of the structure. The optimization of the deployable structures requires an initial selection of the loop types to define the structure parametrically. An initial selection strategy depending on the loads on the structure is important to increase the efficiency of optimization process. Under uniform gravity loads, optimum arrangement for each unit type converges to a similar point. However, in the real world, the loads on the arches are not always uniform and the structure is exposed to nonuniform loadings such as point loads or lateral loads. This work focuses on the performance of various arches with different unit types under lateral and non-uniform vertical loads. Different lateral load and non-uniform gravity loading scenarios are created. For each scenario, the arches with different units are analyzed. In all cases, clear span and height are kept as same. The performance of an arch with a specific unit type for a given load is measured with a score that includes the deformations and the weight of the structure. All the members are assumed to be circular hollow sections with variable diameter and thickness to have a meaningful weight comparison between structures. This work intends to define an initial selection guide for deployable arches under typical non-uniform and lateral loading conditions. (C) 2020 The Authors. Published by Elsevier B.V.Article Citation - WoS: 3Citation - Scopus: 5Classifications for Planimetric Efficiency of Nursing Unit Floors(Middle East Technical University, 2012) Kazanasmaz, Zehra Tuğçe; Tayfur, Gökmen; 02.02. Department of Architecture; 03.03. Department of Civil Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureBu çalışma, Türkiye’deki 15 Devlet Hastanesine ait ‘Hasta Bakım Üniteleri’ verilerini kullanarak, mimarlık alanında oldukça yeni olan Bulanık Mantık metodu ile verimlilik tahmini yapmakta; bu çerçevede bulanık mantık algoritması geliştirerek, Türkiye’de örnek olarak seçilen kamu hastanelerinin plan (planimetric) tasarım verimliliği için sınıflandırmalar geliştirmeye çalışmaktadır. Hasta bakım ve tedavi ünitelerinin kat planlarından hasta kullanım alanları ve dolaşım alanları elde edilerek bulanık mantık modeli alt kümeleri için üyelik fonksiyonları oluşturulmuştur. ‘Mamdanni’ kural sistemi, kuralların ağırlıklarını hesaplamada ‘min’ fonksiyonu, ve ‘max’ kompozisyonu ve ‘centroid’ metodu da bulanık işlemcisi için kullanılmıştır. Girdi değişkenleri olarak hasta kullanım alanları ve dolaşım alanları modellenmiştir. Girdi değişkenleri ile çıktı değişkeni olan tasarım verimliliği arasındaki ilişkiler bulanık mantık kuralları ile ortaya çıkarılmıştır. Varolan hasta bakım ünitelerini incelemek için, verimlilik çıktı değerleri modelden elde edilmiştir. Genel tasarım normları, tasarım ölçütleri ve önceki çalışmalar ışığında ve de bu model aracılığıyla verimlilik sınıfları oluşturulmuştur. Modelde test edilen 15 hastane kat planından altısının düşük verimli sınıf içinde, dokuzunun ise orta verimli sınıf içinde olduğu görülmüştür. Hiçbiri güncel standartlara ve gereksinimlere uygun değildir. Bu çalışmada elde edilen modelin faydası, verimlilik sınıflarının sınır değerlerini belirleme yeteneğinde olmasıdır. Hastanelerin karşılaştırılarak incelenmesi için oluşturulan verimlilik sınıflandırılması başarı ile sonuçlanmıştır. Hastane tasarımcıları ve yöneticileri, mevcut hastanelerin değerlendirmesini ve karşılaştırmaları yapabilmek için bu çalışmadan geribildirim yoluyla bilgi edinebilir. Sonuç olarak, ilgili binalar hakkında karar verme aşmasında(örneğin binanın iyileştirme ihtiyacının olup olmadığı, yeni mekanlara gerek duyulup duyulmadığı gibi) bu modelden faydalanabilirler.Research Project Çok katlı konut yapılarının enerji performansları ile tasarım verimlilik göstergeleri arasındaki ilişkinin belirlenmesi(2012) Kazanasmaz, Zehra Tuğçe; Ekmen, Kenan Evren; Turhan, Cihan; Gökçen Akkurt, Gülden; Erlalelitepe, İlknur; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureEnerji verimliliği, kaliteli konut tasarımında ciddi bir konu olarak önem taşımaktadır. Binaların mimari konfigürasyonlarının ve tasarım normlarının da enerji performansına doğrudan etkisi olduğu bilinmektedir. Avrupa Birliği içerisinde enerji tüketimini azaltmak için çıkartılan enerji verimliliği yasaları dikkate alındığında, Türkiye, halen, Avrupa Birliği’nin en son çıkan Binalarda Enerji Performansı Yönergesi 2010/31/EC’ e uymak için yönetmelikler çıkarmakla yükümlüdür. Türkiye’nin en yeni yönetmeliği, mevcut binaların enerji performansının değerlendirilmesi hakkında bilgi gerektirmektedir. Böylece, bu çalışma İzmir’ deki konut binalarının enerji performanslarını belirlemeyi, istatistiksel analizlerle enerji performansları ile tasarım verimlilik göstergeleri arasındaki ilişkiyi incelemeyi amaçlamıştır. Uygulama projeleri elde edilerek belirli alan bazlı oranlar ve bina ölçüleri mimari tasarım göstergeleri olarak belirlenmiştir. Örnek binaların enerji performansları, Türk standardı olan TS825 ile Avrupa standardı olan EB ISO 13790’ı temel alarak hazırlanan Konutlarda Enerji Performansı Standart Değerlendirme Metodu (KEP-SDM) kullanılarak belirlenmiştir. Sonuçlar bize öylesine bir ipucu sunmaktadır ki değişkenler arasındaki etkileşim ile bunların binaların enerji performansı ve CO2 salımlarına olan etkilerinin düşünülmesi gereklidir. Ayrıca, elde edilen bulgular, ülkemizde örnek seçilen bir şehir olan İzmir’deki konut bina stoğu hakkında da geribildirim sağlamaktadır.Conference Object Citation - Scopus: 1Comfort Based Investigation on Historic Libraries for User Satisfaction and Preservation of Paper-Based Collections(IOP Publishing, 2021) Turhan, Cihan; Topan, Çağrı; Durmuş Arsan, Zeynep; Göksal Özbalta, Türkan; Gökçen Akkurt, Gülden; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureHistoric libraries preserve cultural heritage values while housing rare manuscripts and paper-based collections. The collections in the libraries are deteriorated chemically, biologically and mechanically due to inappropriate indoor environment conditions such as temperature and relative humidity fluctuations and microbiological conditions. Apart from preserving vulnerable paper-based collections, accommodating of a considerable thermal comfort level for visitors is essential in historic libraries. The aim of this study is to analyse indoor environment of a historic library in terms of thermal comfort and preventive conservation of paper-based collections. Izmir National Library, built in 1933, is selected as a case study. Indoor air temperature, relative humidity and air velocity in the library were monitored with a one-year measurement campaign. Meanwhile, thermal comfort of the visitors was assessed with PMV/PPD indices and thermal sensation surveys. The results show that high chemical degradation risk is detected in the library while biological and mechanical degradations are in the low risk zone. On the other hand, 87% and 93% of the visitors feel thermally satisfied in heating and cooling seasons, respectively.Article Citation - WoS: 96Citation - Scopus: 103Comparative Study of a Building Energy Performance Software (kep-Iyte and Ann-Based Building Heat Load Estimation(Elsevier Ltd., 2014-12) Turhan, Cihan; Kazanasmaz, Zehra Tuğçe; Erlalelitepe Uygun, İlknur; Ekmen, Kenan Evren; Gökçen Akkurt, Gülden; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureThe several parameters affect the heat load of a building; geometry, construction, layout, climate and the users. These parameters are complex and interrelated. Comprehensive models are needed to understand relationships among the parameters that can handle non-linearities. The aim of this study is to predict heat load of existing buildings benefiting from width/length ratio, wall overall heat transfer coefficient, area/volume ratio, total external surface area, total window area/total external surface area ratio by using artificial neural networks and compare the results with a building energy simulation tool called KEP-IYTE-ESS developed by Izmir Institute of Technology. A back propagation neural network algorithm has been preferred and both simulation tools were applied to 148 residential buildings selected from 3 municipalities of Izmir-Turkey. Under the given conditions, a good coherence was observed between artificial neural network and building energy simulation tool results with a mean absolute percentage error of 5.06% and successful prediction rate of 0.977. The advantages of ANN model over the energy simulation software are observed as the simplicity, the speed of calculation and learning from the limited data sets.Article Citation - WoS: 18Citation - Scopus: 19A Critical Review on Classification and Terminology of Scissor Structures(Int. Association for Shell and Spatial Structures, 2019) Maden, Feray; Akgün, Yenal; Kiper, Gökhan; Gür, Şebnem; Yar, Müjde; Korkmaz, Koray; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureWhen the existing literature on the research of scissor structures is thoroughly investigated, it is seen that different researchers use different terminologies and classifications especially for the definition of the primary units and the motion type. Some of the studies define the whole geometry based on the geometric properties of the primary scissor units and the unit lines while some other studies define it according to the loops. All these studies use different names for similar elements. This article aims to review the literature on the classification and terminology of scissor structures and represent the state of art on the studies. Tables are represented showing all approaches in the literature. In addition, the article criticizes the missing points of each terminology and definition, and proposes some new terminology. In order to arrive at this aim, different definitions of the primary scissor units and motion types used in key studies in the literature are investigated thoroughly. With several examples, it is demonstrated that naming the scissor units according to the resulting motion type might be misleading and it is better to specify the motion type for the whole structure. A classification for transformation of planar curves is presented.Conference Object Citation - Scopus: 1Decoding and Predicting the Attributes of Urban Public Spaces With Soft Computing Models and Space Syntax Approaches(Education and research in Computer Aided Architectural Design in Europe, 2023) Yönder, Veli Mustafa; Doğan, Fehmi; Çavka, Hasan Burak; Tayfur, Gökmen; Dülgeroğlu, Özüm; 02.02. Department of Architecture; 03.03. Department of Civil Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitecturePeople spend a considerable amount of time in public spaces for a variety of reasons, albeit at various times of the day and during season. Therefore, it is of utmost importance for both urban designers and local authorities to try to gain an understanding of the architectural qualities of these spaces. Within the scope of this study, squares and green parks in Izmir, the third largest city in Turkey, were analyzed in terms of their dimensions, landscape characteristics, the quality of their semi-open spaces, their landmarks, accessibility, and overall aesthetic quality. Using linear predictor, general regression neural networks, multilayer feed-forward neural networks (2-3-4-5-6 nodes), and genetic algorithms, soft computing models were trained in accordance with the results of the conducted analyses. Meanwhile, using space syntax methodologies, a visibility graph analysis and axial map analysis were conducted. The training results (i.e., root mean square error, mean absolute error, bad prediction rates for testing and training phases, and standard deviation of absolute error) were obtained in a comparative table based on training times and root mean square error values. According to the benchmarking table, the network that most accurately predicts the aesthetic score is the 2-node MLFNN, whereas the 6-node MLFN network is the least successful network. © 2023, Education and research in Computer Aided Architectural Design in Europe. All rights reserved.Article Citation - Scopus: 9Design Alternatives of Network of Altmann Linkages(WITPress, 2017-06) Atarer, Fulya; Korkmaz, Koray; Kiper, Gökhan; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 01. Izmir Institute of Technology; 03. Faculty of Engineering; 02. Faculty of ArchitectureThis paper presents a method of building deployable network assemblies derived from the single degree of freedom (DoF) over constrained Altmann linkage as a basic module. The method is based on assembling linkages with common links and joints or overlapping with extra R or 2R joints. New loops are emerged with overlapping method. The networks created have a single DoF, are over-constrained and have both fully deployed and folded configurations. The computer-aided models (CAD) are used to demonstrate these derived novel mechanisms.Conference Object Design of a Reconfigurable Deployable Structure(2014-11-24) Gürcü, Fulya; Korkmaz, Koray; Kiper, Gökhan; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureThis paper introduces a reconfigurable mechanised structure design composed of planar linkage units. The alternative forms that a linkage can be constructed with the same links and connections are called configurations or assembly modes of the linkage. During its motion, the linkage may pass from one assembly mode to another, which is called reconfiguration or assembly mode change. The reconfigurable structure presented in this paper is a single DOF multi-loop mechanised structure which has more than two configurations. Design and position analysis of the mechanism are implemented in Microsoft Excel environment. The link lengths can be varied in this environment and the structure can be simulated by changing input joint parameters. The mechanised reconfigurable structure can be used as a multifunctional canopy which can take any form in a few minutes for urgent needs after disasters, military purpose or public needs.Article Citation - WoS: 6Citation - Scopus: 5Design of Anti-Parallelogram Loop Assemblies(Int. Association for Shell and Spatial Structures, 2019) Gür, Şebnem; Korkmaz, Koray; Kiper, Gökhan; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureScissor mechanisms are frequently used for deployable structures and many studies have been conducted on the subject. Most of the studies consider scissor units as modules in the design process. An alternative approach is to utilize loops as the modules for design. In this paper, the design alternatives of single degree-of-freedom planar linkages comprising anti-parallelogram loops using the loop assembly method is presented. First, scissor mechanisms are reviewed. Next, the types of four-bar loops and the resulting linkages in the literature are introduced and those which are yet to be explored, anti-parallelogram being one of them, are identified. Then the loop assembly method and the examples in the literature are reviewed. As a method to form as many alternatives as possible, symmetry operations are proposed. Suitable frieze symmetry groups utilized for obtaining the assemblies are explained and the anti-parallelogram loop patterns are derived. Next, the single degree-of-freedom linkages are obtained from the loop assemblies. Finally, a selection of the resulting linkages with novel properties are presented. This study shows that loop assemblies are efficient in systematic type synthesis of scissor linkages, some types of which could not be foreseen by using units as modules.Article Citation - WoS: 1Citation - Scopus: 1Design of Demountable Reciprocal Frames With New Geometric Properties(Int. Association for Shell and Spatial Structures, 2022-09) Özen, Gülçin; Kiper, Gökhan; Korkmaz, Koray; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureThis study aims to develop missing geometric knowledge for demountable reciprocal frames (RF). While designing a demountable RF, one should know the initial, in-process and final form of the RF. These processes require some specific geometric knowledge. There are some deficiencies about geometric properties in the previous studies about demountable RFs. In this study, the positions and the orientations of the nexors are found by using the Denavit-Hartenberg parameters. This information gives where the joints are placed, how they are oriented and take position according to one another. Besides, the influence of engagement length on the fan height and the base edge are analyzed. Thereby one will be able to find out how much space the RF covers with the known base edge. With the geometric knowledge obtained from this study, demountable RFs having different engagement lengths can be produced with the same nexors.Conference Object Citation - WoS: 6Citation - Scopus: 8The Effect of Spatial Interventions on Historic Buildings' Indoor Climate (case Study: Tire Necip Paşa Library, Izmir-Turkey)(Elsevier Ltd., 2017) Coşkun, Turgay; Gülhan, Özcan; Şahin, Cem Doğan; Durmuş Arsan, Zeynep; Gökçen Akkurt, Gülden; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 01. Izmir Institute of Technology; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 02. Faculty of ArchitectureThe indoor climate of historic libraries should meet rigorous requirements related to human thermal comfort and conservation of books, manuscripts and cultural proper-ties. Paper based collections in historic libraries can be deteriorated chemically, mechanically and biologically because of inadequate indoor climate conditions. In this paper, Necip Paşa Library, the historic library located in Tire-Izmir, Turkey, was selected as a case study. The chemical, mechanical and biological degradation risks on the manuscripts were evaluated based on the indoor climate parameters measured for one year period. The Library, consisting of a main hall, a manuscript zone and an entrance hall, was modelled via the dynamic simulation software, Design Builder. Calibration of the model was conducted with respect to the measured indoor temperature and relative humidity values. The portico/Revak at the south facade of Library was converted into the entrance hall by wooden framed windows in 1930. To be able to see the effect of that intervention on the indoor climate (correspondingly on degradation risk of the manuscripts), a new model, namely semi-open model, was created and simulated. A remarkable change has not been observed on chemical degradation risk when the results of semi-open and existing library models were compared, while mechanical and biological degradation risks were less in semi-open model.Conference Object Citation - Scopus: 2Emerging Concept of Human Centric Lighting in Literature Review(IEEE, 2023) Kazanasmaz, Zehra Tuğçe; Köse, Fatma Büşra; Tayfur, Gökmen; 02.02. Department of Architecture; 03.03. Department of Civil Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureHuman centric lighting is an umbrella concept which covers human health and well-being in general. As the conventional lighting techniques are based on horizontal workplane illuminance, it drives from the vertical eye level illuminance and its spectral distribution triggering the non-visual effects on humans. That is named as melanopic illuminance consequently. Its metrics have taken their place in lighting design literature and applications, with emergence of related standards subsequently. This literature overview contributes about the understanding the meaning human centric lighting due to transition from visual to non-visual effects of light, and how they direct recent research through light's impacts on human performance, emotions health and well-being, and relations to energy saving even. The shift from the concept of human centric lighting to circadian lighting design is obvious in very current studies. © 2023 IEEE.Article A Fuzzy Logic Model To Classify Design Efficiency of Nursing Unit Floors(Yıldız Teknik Üniversitesi, 2010) Kazanasmaz, Tugce; Tayfur, Gokmen; 02.02. Department of Architecture; 03.03. Department of Civil Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureThis study was conducted to determine classifications for the planimetric design efficiency of certain public hospitals by developing a fuzzy logic algorithm. Utilizing primary areas and circulation areas from nursing unit floor plans, the study employed triangular membership functions for the fuzzy subsets. The input variables of primary areas per bed and circulation areas per bed were fuzzified in this model. The relationship between input variables and output variable of design efficiency were displayed as a result of fuzzy rules. To test existing nursing unit floors, efficiency output values were obtained and efficiency classes were constructed by this model in accordance with general norms, guidelines and previous studies. The classification of efficiency resulted from the comparison of hospitals.Article Citation - WoS: 6Citation - Scopus: 9Impact of Climate Change on Indoor Environment of Historic Libraries in Mediterranean Climate Zone(Inderscience Enterprises, 2019) Turhan, Cihan; Durmuş Arsan, Zeynep; Gökçen Akkurt, Gülden; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureMost historic library buildings house valuable paper-based collections that are kept in unconditioned environments. This vulnerable cultural heritage is expected to be highly affected by climate change in the future. In this study, indoor microclimate of an unconditioned historic library, Necip Pasa Library (Izmir, Turkey) is analysed for existing conditions and future climate data. The measured and predicted indoor microclimate data from 'present' till 2080s are used to determine possible chemical degredation risk on library collection and human comfort. Comparison of periodic results of future climate data indicates an increase in temperature that could cause both an increase in chemical degredation risk on the library collection and a decline in thermal comfort conditions. Mitigation of climate change effects on library collection and human comfort requires taking some actions such as adding light and adaptive mechanical solutions.Article Citation - WoS: 7Citation - Scopus: 7The Importance of Internal Heat Gains for Building Cooling Design(Yıldız Teknik Üniversitesi, 2017) Coşkun, Turgay; Turhan, Cihan; Durmuş Arsan, Zeynep; Gökçen Akkurt, Gülden; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureThis paper aims to investigate the effect of internal heat gains on the cooling load of a building. The house occupied by three adult men is selected as the case study for paper. The house is in the third floor of the apartment. The apartment has four flats and it has no insulation around the external walls. The heat dissipation from lighting devices, electrical equipment and the occupants are calculated by using the DesignBuilder v4 Beta release simulation program. The temperature of the house is observed during three weeks by using hobo data loggers and calibration of the measurements is made with respect to weather data file of the flat. Detailed schedule based on time of operation and occupancy is prepared to get more accurate results. Annual energy consumption and cooling load of the house is determined by using the dynamic simulation program.