Please use this identifier to cite or link to this item:
https://hdl.handle.net/11147/10381
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Toprak, Kasım | tr |
dc.contributor.author | Ouedraogo, Kiswendsida Elias | - |
dc.date.accessioned | 2021-01-24T18:34:23Z | - |
dc.date.available | 2021-01-24T18:34:23Z | - |
dc.date.issued | 2020 | - |
dc.identifier.issn | 1302-0900 | - |
dc.identifier.issn | 2147-9429 | - |
dc.identifier.uri | https://hdl.handle.net/11147/10381 | - |
dc.identifier.uri | https://doi.org/10.2339/politeknik.517603 | - |
dc.identifier.uri | https://search.trdizin.gov.tr/yayin/detay/423371 | - |
dc.description.abstract | As global warming and water scarcity issues continue to grow, it is essential to increase resources efficiency for air conditioners and power plants. In order to increase the efficiency, the systems need to be modified to take the advantages of the low night temperature and thermal storage tanks. In this study, the low night temperature and thermal storage tanks effects on the cooling tower is studied using TRNSYS. Using a chiller operating from 8:00 to 16:00 as a case study, hot water from the condenser is partially stored on daytime and cooled slowly during the night. The storage tank volume is optimized by considering two big tanks and five small tanks. The results show that night cooling reduces cooling water temperature by 5.8 degrees C or 21.8% while the cooling efficiency is increased by 36%. The thermal storage tanks enable to have the low continuous flow rate and help to reduce the fan power by 67.1%. On the storage side, compared to two tanks system, the tanks volume is reduced by 16.5% when 5 tanks are used. In theory this reduction can go up to 50% by increasing the number of tanks and reducing their individual size. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Gazi Üniversitesi | tr |
dc.relation.ispartof | Politeknik Dergisi | tr |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Cooling tower | en_US |
dc.subject | Thermal storage | en_US |
dc.subject | Night cooling | en_US |
dc.title | Performance analysis of thermal storage assisted cooling tower with night cooling | en_US |
dc.type | Article | en_US |
dc.institutionauthor | Ouedraogo, Kiswendsida Elias | - |
dc.institutionauthor | Toprak, Kasım | tr |
dc.department | İzmir Institute of Technology. Mechanical Engineering | en_US |
dc.department | İzmir Institute of Technology. Energy Systems Engineering | en_US |
dc.identifier.volume | 23 | en_US |
dc.identifier.issue | 4 | en_US |
dc.identifier.startpage | 1027 | en_US |
dc.identifier.endpage | 1035 | en_US |
dc.identifier.wos | WOS:000581901200009 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | tr |
dc.identifier.doi | 10.2339/politeknik.517603 | - |
dc.identifier.trdizinid | 423371 | en_US |
dc.identifier.scopusquality | N/A | - |
item.fulltext | With Fulltext | - |
item.grantfulltext | open | - |
item.languageiso639-1 | en | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.openairetype | Article | - |
crisitem.author.dept | 03.10. Department of Mechanical Engineering | - |
Appears in Collections: | Energy Systems Engineering / Enerji Sistemleri Mühendisliği Mechanical Engineering / Makina Mühendisliği TR Dizin İndeksli Yayınlar / TR Dizin Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Files in This Item:
File | Size | Format | |
---|---|---|---|
10.2339-politeknik.517603-823721.pdf | 2.56 MB | Adobe PDF | View/Open |
CORE Recommender
WEB OF SCIENCETM
Citations
1
checked on Nov 9, 2024
Page view(s)
288
checked on Nov 18, 2024
Download(s)
68
checked on Nov 18, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.