Please use this identifier to cite or link to this item:
https://hdl.handle.net/11147/10047
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Urkaç, Emel Sokullu | - |
dc.contributor.author | Öztarhan, Ahmet | - |
dc.contributor.author | Tıhmınlıoğlu, Funda | - |
dc.contributor.author | Deliloğlu, İsmet Gürhan | - |
dc.contributor.author | İz, Sultan Gülce | - |
dc.contributor.author | Oks, Efim | - |
dc.contributor.author | Ila, Daryush | - |
dc.date.accessioned | 2021-01-24T18:32:05Z | - |
dc.date.available | 2021-01-24T18:32:05Z | - |
dc.date.issued | 2009 | - |
dc.identifier.isbn | 978-0-7354-0633-9 | - |
dc.identifier.issn | 0094-243X | - |
dc.identifier.issn | 1551-7616 | - |
dc.identifier.uri | https://hdl.handle.net/11147/10047 | - |
dc.description | 20th International Conference on Application of Accelerators in Research and Industry | en_US |
dc.description.abstract | Implanted biomedical prosthetic devices are intended to perform safely, reliably and effectively in the human body thus the materials used for orthopedic devices should have good biocompatibility. Ultra High Molecular Weight Poly Ethylene (UHMWPE) has been commonly used for total hip joint replacement because of its very good properties. In this work, UHMWPE samples were Ag and Ag+N ion implanted by using the Metal-Vapor Vacuum Arc (MEVVA) ion implantation technique. Samples were implanted with a fluency of 1017 ion/cm2 and extraction voltage of 30 kV. Rutherford Backscattering Spectrometry (RBS) was used for surface studies. RBS showed the presence of Ag and N on the surface. Cell attachment properties investigated with model cell lines (L929 mouse fibroblasts) to demonstrate that the effect of Ag and Ag+N ion implantation can favorably influence the surface of UHMWPE for biomedical applications. Scanning electron microscopy (SEM) was used to demonstrate the cell attachment on the surface. Study has shown that Ag+N ion implantation represents more effective cell attachment properties on the UHMWPE surfaces. | en_US |
dc.description.sponsorship | Univ N Texas, Sandia Natl Lab | en_US |
dc.language.iso | en | en_US |
dc.publisher | American Institute of Physics | en_US |
dc.relation.ispartof | AIP Conference Proceedings | en_US |
dc.relation.ispartofseries | AIP Conference Proceedings | - |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Ag | en_US |
dc.subject | UHMWPE | en_US |
dc.subject | biocompatibility | en_US |
dc.subject | cell attachment | en_US |
dc.title | The effect of Ag and Ag plus N Ion implantation on cell attachment properties | en_US |
dc.type | Conference Object | en_US |
dc.institutionauthor | Tıhmınlıoğlu, Funda | - |
dc.department | İzmir Institute of Technology. Chemical Engineering | en_US |
dc.identifier.volume | 1099 | en_US |
dc.identifier.startpage | 528 | en_US |
dc.identifier.endpage | + | en_US |
dc.identifier.wos | WOS:000265828500115 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.wosquality | N/A | - |
dc.identifier.scopusquality | Q4 | - |
item.fulltext | No Fulltext | - |
item.grantfulltext | none | - |
item.languageiso639-1 | en | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.openairetype | Conference Object | - |
crisitem.author.dept | 03.02. Department of Chemical Engineering | - |
Appears in Collections: | WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.