03. Mimarlık Fakültesi / Faculty of Architecture
Permanent URI for this communityhttps://hdl.handle.net/11147/21
Browse
Browsing 03. Mimarlık Fakültesi / Faculty of Architecture by Author "03.06. Department of Energy Systems Engineering"
Now showing 1 - 18 of 18
- Results Per Page
- Sort Options
Conference Object Akifere Yağıştan Süzülme Miktarının Sondaj Verileri Kullanılarak Tahmin Edilmesi: Alaşehir (manisa) Havzası(TMMOB Jeoloji Mühendisleri Odası, 2018) Tonkul, Serhat; Baba, Alper; Şimşek, Celalettin; Tayfur, Gökmen; Durukan, Seda; Kumanlıoğlu, Ahmet; Demirkesen, Ali Can; 03.06. Department of Energy Systems Engineering; 02.03. Department of City and Regional Planning; 03.03. Department of Civil Engineering; 03. Faculty of Engineering; 02. Faculty of Architecture; 01. Izmir Institute of TechnologySon yıllarda iklim değişikliğine bağlı su kullanımının artması ve buna ek olarak aşırı nüfus artışı, yeraltısuyu kullanımını arttırmakta ve su kaynaklarını tehdit etmektedir. Su kaynaklarının sürdürülebilirliğinin sağlanması için barajlar ve yapay göller inşa edilmekte, ancak bu yapıların geniş yüzey alanlarında çok fazla buharlaşma görülmektedir. Dolayısı ile yeraltı suyunun, buharlaşma kayıplarının yaşanmadığı direkt yağış ile beslenen yapay beslenmesi önem kazanmaktadır. Yapay beslenme, havzalardaki suyu fazla buharlaşmadan korur ve su kaynaklarının potansiyelini artırıp, sürdürülebilirliğini sağlar. Bu çalışma kapsamında nümerik metotlar kullanılarak, Alaşehir (Manisa) havzasında alüvyon akiferin beslenmesinin belirlenmesi amaçlanmıştır. Türkiye’nin batısında yer alan ve ülkenin %2’sini oluşturan Gediz Havzası, önemli bir yeraltı suyu potansiyelinin olduğu ve kullanıldığı alan konumundadır.Conference Object Citation - WoS: 20Citation - Scopus: 25Applying Underfloor Heating System for Improvement of Thermal Comfort in Historic Mosques: the Case Study of Salepçioglu Mosque, Izmir, Turkey(Elsevier Ltd., 2017) Bughrara, Khaled S. M.; Durmuş Arsan, Zeynep; Gökçen Akkurt, Gülden; 02.02. Department of Architecture; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureMosques differ from other types of buildings by having an intermittent operation schedule. Due to five prayer times per day throughout the year, mosques are fully or partially, yet periodically, occupied. This paper examines the potential of using an underfloor heating system for improvement of indoor thermal comfort in a historic mosque, which is naturally ventilated, heated and cooled, based on adaptive thermal comfort method. The selected Salepçioǧlu Mosque, housing valuable wall paintings, was built in 1905 in KemeraltI, Izmir, Turkey. It requires specific attention with its cultural heritage value. Firstly, indoor microclimate of the Mosque was monitored for one-year period of 2014-15. Then, dynamic simulation modelling tool, DesignBuilder v.4.2 was used to create the physical model of the Mosque. The ASHRAE Guideline 14 indices were utilized to calibrate the model, by comparing simulated and measured indoor air temperature to achieve hourly errors within defined ranges. The results of calibrated baseline model indicate that the Mosque does not satisfy acceptable thermal comfort levels for winter months that provided by the adaptive method. Then, the effect of underfloor heating was examined in the second model by the.Research Project Çok katlı konut yapılarının enerji performansları ile tasarım verimlilik göstergeleri arasındaki ilişkinin belirlenmesi(2012) Kazanasmaz, Zehra Tuğçe; Ekmen, Kenan Evren; Turhan, Cihan; Gökçen Akkurt, Gülden; Erlalelitepe, İlknur; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureEnerji verimliliği, kaliteli konut tasarımında ciddi bir konu olarak önem taşımaktadır. Binaların mimari konfigürasyonlarının ve tasarım normlarının da enerji performansına doğrudan etkisi olduğu bilinmektedir. Avrupa Birliği içerisinde enerji tüketimini azaltmak için çıkartılan enerji verimliliği yasaları dikkate alındığında, Türkiye, halen, Avrupa Birliği’nin en son çıkan Binalarda Enerji Performansı Yönergesi 2010/31/EC’ e uymak için yönetmelikler çıkarmakla yükümlüdür. Türkiye’nin en yeni yönetmeliği, mevcut binaların enerji performansının değerlendirilmesi hakkında bilgi gerektirmektedir. Böylece, bu çalışma İzmir’ deki konut binalarının enerji performanslarını belirlemeyi, istatistiksel analizlerle enerji performansları ile tasarım verimlilik göstergeleri arasındaki ilişkiyi incelemeyi amaçlamıştır. Uygulama projeleri elde edilerek belirli alan bazlı oranlar ve bina ölçüleri mimari tasarım göstergeleri olarak belirlenmiştir. Örnek binaların enerji performansları, Türk standardı olan TS825 ile Avrupa standardı olan EB ISO 13790’ı temel alarak hazırlanan Konutlarda Enerji Performansı Standart Değerlendirme Metodu (KEP-SDM) kullanılarak belirlenmiştir. Sonuçlar bize öylesine bir ipucu sunmaktadır ki değişkenler arasındaki etkileşim ile bunların binaların enerji performansı ve CO2 salımlarına olan etkilerinin düşünülmesi gereklidir. Ayrıca, elde edilen bulgular, ülkemizde örnek seçilen bir şehir olan İzmir’deki konut bina stoğu hakkında da geribildirim sağlamaktadır.Conference Object Citation - Scopus: 1Comfort Based Investigation on Historic Libraries for User Satisfaction and Preservation of Paper-Based Collections(IOP Publishing, 2021-10) Turhan, Cihan; Topan, Çağrı; Durmuş Arsan, Zeynep; Göksal Özbalta, Türkan; Gökçen Akkurt, Gülden; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureHistoric libraries preserve cultural heritage values while housing rare manuscripts and paper-based collections. The collections in the libraries are deteriorated chemically, biologically and mechanically due to inappropriate indoor environment conditions such as temperature and relative humidity fluctuations and microbiological conditions. Apart from preserving vulnerable paper-based collections, accommodating of a considerable thermal comfort level for visitors is essential in historic libraries. The aim of this study is to analyse indoor environment of a historic library in terms of thermal comfort and preventive conservation of paper-based collections. Izmir National Library, built in 1933, is selected as a case study. Indoor air temperature, relative humidity and air velocity in the library were monitored with a one-year measurement campaign. Meanwhile, thermal comfort of the visitors was assessed with PMV/PPD indices and thermal sensation surveys. The results show that high chemical degradation risk is detected in the library while biological and mechanical degradations are in the low risk zone. On the other hand, 87% and 93% of the visitors feel thermally satisfied in heating and cooling seasons, respectively.Article Citation - WoS: 96Citation - Scopus: 103Comparative Study of a Building Energy Performance Software (kep-Iyte and Ann-Based Building Heat Load Estimation(Elsevier Ltd., 2014-12) Turhan, Cihan; Kazanasmaz, Zehra Tuğçe; Erlalelitepe Uygun, İlknur; Ekmen, Kenan Evren; Gökçen Akkurt, Gülden; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureThe several parameters affect the heat load of a building; geometry, construction, layout, climate and the users. These parameters are complex and interrelated. Comprehensive models are needed to understand relationships among the parameters that can handle non-linearities. The aim of this study is to predict heat load of existing buildings benefiting from width/length ratio, wall overall heat transfer coefficient, area/volume ratio, total external surface area, total window area/total external surface area ratio by using artificial neural networks and compare the results with a building energy simulation tool called KEP-IYTE-ESS developed by Izmir Institute of Technology. A back propagation neural network algorithm has been preferred and both simulation tools were applied to 148 residential buildings selected from 3 municipalities of Izmir-Turkey. Under the given conditions, a good coherence was observed between artificial neural network and building energy simulation tool results with a mean absolute percentage error of 5.06% and successful prediction rate of 0.977. The advantages of ANN model over the energy simulation software are observed as the simplicity, the speed of calculation and learning from the limited data sets.Conference Object Citation - WoS: 6Citation - Scopus: 8The Effect of Spatial Interventions on Historic Buildings' Indoor Climate (case Study: Tire Necip Paşa Library, Izmir-Turkey)(Elsevier Ltd., 2017) Coşkun, Turgay; Gülhan, Özcan; Şahin, Cem Doğan; Durmuş Arsan, Zeynep; Gökçen Akkurt, Gülden; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 01. Izmir Institute of Technology; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 02. Faculty of ArchitectureThe indoor climate of historic libraries should meet rigorous requirements related to human thermal comfort and conservation of books, manuscripts and cultural proper-ties. Paper based collections in historic libraries can be deteriorated chemically, mechanically and biologically because of inadequate indoor climate conditions. In this paper, Necip Paşa Library, the historic library located in Tire-Izmir, Turkey, was selected as a case study. The chemical, mechanical and biological degradation risks on the manuscripts were evaluated based on the indoor climate parameters measured for one year period. The Library, consisting of a main hall, a manuscript zone and an entrance hall, was modelled via the dynamic simulation software, Design Builder. Calibration of the model was conducted with respect to the measured indoor temperature and relative humidity values. The portico/Revak at the south facade of Library was converted into the entrance hall by wooden framed windows in 1930. To be able to see the effect of that intervention on the indoor climate (correspondingly on degradation risk of the manuscripts), a new model, namely semi-open model, was created and simulated. A remarkable change has not been observed on chemical degradation risk when the results of semi-open and existing library models were compared, while mechanical and biological degradation risks were less in semi-open model.Article Citation - WoS: 38Citation - Scopus: 42Geological and Hydrogeochemical Properties of Geothermal Systems in the Southeastern Region of Turkey(Elsevier Ltd., 2019-03) Baba, Alper; Şaroğlu, Fuat; Akkuş, I.; Özel, Nedret; Yeşilnacar, Mehmet İrfan; Nalbantçılar, Mahmut Tahir; Demir, Mustafa Muammer; Gökçen, Gülden; Arslan, Ş.; Dursun, N.; Uzelli, Taygun; Yazdani, Hamidreza; 03.03. Department of Civil Engineering; 03.06. Department of Energy Systems Engineering; 01.01. Units Affiliated to the Rectorate; 03.09. Department of Materials Science and Engineering; 01. Izmir Institute of Technology; 03. Faculty of EngineeringThe Anatolia region is one of the most seismically active regions in the world. It has a considerably high level of geothermal energy potential thanks to its geological and tectonic settings. The Southeastern Anatolia Region (GAP) is located in the south of Bitlis-Zagros Suture Zone (BZSZ) which is in the Arabian foreland. During the neotectonic period, the folded structures have been developed under the influence of tectonic compression from the Upper Miocene in the GAP Region where it is closely related to active tectonics. These tectonic activities produce more geothermal resources. Few studies have been carried out in this region for geothermal energy. Limited portions of the geothermal resources have been used both for thermal tourism and greenhouses in the GAP region. The aim of this study is to determine geological, tectonic and hydrogeochemical properties of a geothermal system in the GAP Region. The result indicates that the surface temperatures of geothermal fluids are from 20 to 84.5 °C A large number of abandoned oil wells, whose temperature reaches 140 °C, are found in the region. Also, hydrogeochemical results show that deep circulated geothermal fluids are enriched with Na-Cl and shallow geothermal system fluids have Na−HCO 3 and Ca-SO 4 characters because of cold water mixing and water-rock interaction. Cold waters are generally of Ca-Mg−HCO 3 and Ca−HCO 3 type. Cation geothermometers were used for determining reservoir temperature of the geothermal resources in the region. The results show that the reservoir temperature of these geothermal resources ranges from 50 °C to 200 °C. The isotope data (oxygen-18, deuterium and tritium) suggests that geothermal fluid is formed by local recharge and deep circulation.Article Citation - WoS: 1Citation - Scopus: 1Groundwater Recharge Estiaton in the Alaşehir Sub-Basin Using Hydro-Geochemical Data; Alaşehir Case Study(Springer, 2021) Tonkul, Serhat; Baba, Alper; Şimşek, Celalettin; Demirkesen, Ali Can; 03.06. Department of Energy Systems Engineering; 02.03. Department of City and Regional Planning; 03.03. Department of Civil Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureThe issue of groundwater recharge has gained importance in countries where there is not enough water supply to the aquifer. However, groundwater recharge is a difficult parameter to determine. This difficulty stems from factors such as the location of the area to be studied, time, cost, and hydrological data. Numerical, isotope, and chemical approaches are used in groundwater recharge investigations. Numerical and chemical approaches are more costly and time-consuming than chemical approaches. This study aims to ascertain alluvial aquifer recharge in Alaehir (Manisa) sub-basin using chemical approaches (Chloride Mass Balance Method) and its applicability. For this purpose, research wells were drilled at 25 different points in the alluvial aquifer, water sampling was done in wet and dry periods, and rainwater water samples were collected. Groundwater recharge was calculated by using chemical approaches from the chloride concentrations of the water samples collected. An annual average of 74.84 mm of recharge was found in the Alaehir sub-basin. This value corresponds to 16.38% of annual rainfall. At the same time, it was examined the groundwater and geothermal mixing mechanism to demonstrate the applicability of the Chloride Mass Balance Method. It was concluded that geothermal fluid in Alaehir sub-basin mixed with groundwater at a rate of 17%.Article Citation - WoS: 15Citation - Scopus: 18Groundwater Recharge Estimation Using Hydrus 1d Model in Alaşehir Sub-Basin of Gediz Basin in Turkey(Springer Verlag, 2019-10) Tonkul, Serhat; Baba, Alper; Şimşek, Celalettin; Durukan, Seda; Demirkesen, Ali Can; Tayfur, Gökmen; 03.06. Department of Energy Systems Engineering; 02.03. Department of City and Regional Planning; 03.03. Department of Civil Engineering; 03. Faculty of Engineering; 02. Faculty of Architecture; 01. Izmir Institute of TechnologyGediz Basin, located in the western part of Turkey constituting 2% land of the country, has an important groundwater potential in the area. Alasehir sub-basin, located in the southeast of the Gediz Basin and subject to the extensive withdrawal for the irrigation, constitutes the study area. Natural recharge to the sub-basin due to precipitation is numerically investigated in this study. For this purpose, 25 research wells, whose depths range from 20 to 50 m, were drilled to observe the recharge and collect the necessary field data for the numerical model. Meteorological data were collected from 3 weather stations installed in the study area. The numerical model HYDRUS was calibrated using the field water content data. Soil characterization was done on the core samples; the aquifer characterization was performed, and the alluvial aquifer recharge due to precipitation was calculated. As a result, the computed recharge value ranges from 21.78 to 68.52 mm, with an average value of 43.09 mm. According to the numerical model, this amount of recharge corresponds to 10% of the amount of annual rainfall.Article Citation - WoS: 6Citation - Scopus: 9Impact of Climate Change on Indoor Environment of Historic Libraries in Mediterranean Climate Zone(Inderscience Enterprises, 2019) Turhan, Cihan; Durmuş Arsan, Zeynep; Gökçen Akkurt, Gülden; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureMost historic library buildings house valuable paper-based collections that are kept in unconditioned environments. This vulnerable cultural heritage is expected to be highly affected by climate change in the future. In this study, indoor microclimate of an unconditioned historic library, Necip Pasa Library (Izmir, Turkey) is analysed for existing conditions and future climate data. The measured and predicted indoor microclimate data from 'present' till 2080s are used to determine possible chemical degredation risk on library collection and human comfort. Comparison of periodic results of future climate data indicates an increase in temperature that could cause both an increase in chemical degredation risk on the library collection and a decline in thermal comfort conditions. Mitigation of climate change effects on library collection and human comfort requires taking some actions such as adding light and adaptive mechanical solutions.Article Citation - WoS: 7Citation - Scopus: 7The Importance of Internal Heat Gains for Building Cooling Design(Yıldız Teknik Üniversitesi, 2017-01) Coşkun, Turgay; Turhan, Cihan; Durmuş Arsan, Zeynep; Gökçen Akkurt, Gülden; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureThis paper aims to investigate the effect of internal heat gains on the cooling load of a building. The house occupied by three adult men is selected as the case study for paper. The house is in the third floor of the apartment. The apartment has four flats and it has no insulation around the external walls. The heat dissipation from lighting devices, electrical equipment and the occupants are calculated by using the DesignBuilder v4 Beta release simulation program. The temperature of the house is observed during three weeks by using hobo data loggers and calibration of the measurements is made with respect to weather data file of the flat. Detailed schedule based on time of operation and occupancy is prepared to get more accurate results. Annual energy consumption and cooling load of the house is determined by using the dynamic simulation program.Article Citation - WoS: 19Citation - Scopus: 21Integration of Energy-Efficient Ventilation Systems in Historic Buildings—review and Proposal of a Systematic Intervention Approach(MDPI, 2021) Rieser, Alexander; Pfluger, Rainer; Troi, Alexandra; Herrera-Avellanosa, Daniel; Thomsen, Kirsten Engelund; Rose, Jorgen; Durmuş Arsan, Zeynep; Gökçen Akkurt, Gülden; Kopeinig, Gerhard; Guyot, Gaëlle; 02.02. Department of Architecture; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureHistoric building restoration and renovation requires sensitivity to the cultural heritage, historic value, and sustainability (i.e., building physics, energy efficiency, and comfort) goals of the project. Energy-efficient ventilation such as demand-controlled ventilation and heat recovery ventilation can contribute to the aforementioned goals, if ventilation concepts and airflow distribution are planned and realized in a minimally invasive way. Compared to new buildings, the building physics of historic buildings are more complicated in terms of hygrothermal performance. In particular, if internal insulation is applied, dehumidification is needed for robust and risk-free future use, while maintaining the building's cultural value. As each ventilation system has to be chosen and adapted individually to the specific building, the selection of the appropriate system type is not an easy task. For this reason, there is a need for a scientifically valid, systematic approach to pair appropriate ventilation system and airflow distribution solutions with historical buildings. This paper provides an overview of the interrelationships between heritage conservation and the need for ventilation in energy-efficient buildings, regarding building physics and indoor environmental quality. Furthermore, a systematic approach based on assessment criteria in terms of heritage significance of the building, building physics (hygrothermal performance), and building services (energy efficiency, indoor air quality, and comfort rating) according to the standard EN 16883:2017 are applied.Article Citation - WoS: 28Citation - Scopus: 37Investigation of Indoor Microclimate of Historic Libraries for Preventive Conservation of Manuscripts. Case Study: Tire Necip Paşa Library, Izmir-Turkey(Elsevier Ltd., 2017-04) Şahin, Cem Doğan; Çoşkun, Turgay; Durmuş Arsan, Zeynep; Gökçen Akkurt, Gülden; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 01. Izmir Institute of Technology; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 02. Faculty of ArchitectureConservation of library collections requires an interdisciplinary approach. Dealing with the agents of deterioration via curative and preventive conservation methods has become a significant goal with new standards and norms in recent years. Preventive conservation aims indirect physical interventions such as climate control, good housekeeping and pest management. The aim of this study is to assess the degradation potential of indoor climate on valuable manuscripts that date back to 12th century, in a historic library in Tire-İzmir, Turkey. Through the study, first the library, namely Necip Paşa Library was continuously monitored by measurements of thermo-hygrometric parameters for one year. Then, the measured data were evaluated for the risk assessment based on the control classes of ASHRAE Chapter 21 to evaluate the mechanical, chemical and biological degradation risks. Finally, the conservation-oriented measures were proposed in order to keep the manuscripts under the better conditions. Results suggest that introducing a heating, ventilation and air-conditioning system to the building should be considered as the last option since natural hygrothermal behavior of the library gives reasonably sufficient evidences to prevent the manuscripts from degradations to some extent. Therefore, passive solutions should be given higher priorities not to disturb environmental past of the historic library.Article Citation - WoS: 23Citation - Scopus: 26On the Relation Between Architectural Considerations and Heating Energy Performance of Turkish Residential Buildings in Izmir(Elsevier Ltd., 2014-04) Kazanasmaz, Zehra Tuğçe; Erlalelitepe Uygun, İlknur; Gökçen Akkurt, Gülden; Turhan, Cihan; Ekmen, Kenan Evren; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureBy considering the energy efficiency legislations among the European Union, Turkey is responsible to provide regulations to comply for the latest European Energy Performance of Buildings Directive 2010/31/EC. New legislation in Turkey requires information about the evaluation of energy performance of existing buildings. This study aimed to determine energy performance of residential buildings in Izmir, regarding significant relationships between their performance and architectural configuration through statistical analysis. The focus was on the heating energy consumption due to Energy Efficiency Law (2007) and Building Energy Performance Regulation (2008), and Standard Assessment Method for Energy Performance of Dwellings (KEP-SDM). This energy performance assessment method was based on Turkish standard TS 825, and European standard EN ISO 13790. It is known that architectural configuration of buildings and design norms have impact on energy performance of buildings. However, emphasis was given on significant values of architectural considerations through certain area-based ratios. The levels of these ratios were matched with the levels of energy consumption. By this, the consideration was to take early-precautions against high energy consumptions in the early design stage and to enhance legislation by adding recommendations of concrete architectural values. These would assist to predict the level of energy performance in the early design phase. Findings would provide feedback information on the residential building stock in İzmir, Turkey.Article Citation - WoS: 7Citation - Scopus: 8Performance Indices of Soft Computing Models To Predict the Heat Load of Buildings in Terms of Architectural Indicators(Yıldız Teknik Üniversitesi, 2017-08) Turhan, Cihan; Kazanasmaz, Zehra Tuğçe; Gökçen Akkurt, Gülden; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureThis study estimates the heat load of buildings in Izmir/Turkey by three soft computing (SC) methods; Artificial Neural Networks (ANNs), Fuzzy Logic (FL) and Adaptive Neuro-based Fuzzy Inference System (ANFIS) and compares their prediction indices. Obtaining knowledge about what the heat load of buildings would be in architectural design stage is necessary to forecast the building performance and take precautions against any possible failure. The best accuracy and prediction power of novel soft computing techniques would assist the practical way of this process. For this purpose, four inputs, namely, wall overall heat transfer coefficient, building area/ volume ratio, total external surface area and total window area/total external surface area ratio were employed in each model of this study. The predicted heat load is evaluated comparatively using simulation outputs. The ANN model estimated the heat load of the case apartments with a rate of 97.7% and the MAPE of 5.06%; while these ratios are 98.6% and 3.56% in Mamdani fuzzy inference systems (FL); 99.0% and 2.43% in ANFIS. When these values were compared, it was found that the ANFIS model has become the best learning technique among the others and can be applicable in building energy performance studies.Article Citation - WoS: 18Citation - Scopus: 23Thermal Comfort Analysis of Historical Mosques. Case Study: the Ulu Mosque, Manisa, Turkey(Elsevier, 2021) Diler, Yusuf; Turhan, Cihan; Durmuş Arsan, Zeynep; Gökçen Akkurt, Gülden; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology; 02. Faculty of ArchitectureMosques are sanctuary places for Muslims where they can perform their religious activities and also can communicate with each other. On the other hand, historical mosques may contain artworks which have cultural heritage values. These mosques originally have not any Heating, Ventilating and Air Conditioning systems. For this reason, obtaining thermal comfort becomes a significant issue. In this study, a systematic approach on monitoring and evaluating thermal comfort of historical mosques were developed. As a case study, The Ulu Mosque, Manisa/Turkey was monitored from 2015 to 2018, and thermal comfort evaluation of the mosque was conducted during prayer times based on the method provided by ISO 7730. A dynamic Building Energy Performance Software, DesignBuilder, was used to model the mosque, and the model was calibrated by using hourly indoor temperature data. The calibrated model was then used to evaluate existing conditions of the mosque and develop retrofitting scenarios in order to increase thermal comfort of prayers. Thirteen different scenarios were proposed to improve thermal comfort of prayers during worship periods. The results were evaluated according to EN 16883 for conservation of cultural heritage of the mosque. Electrical radiator heating with intermittent operating schedules was obtained as the best scenario to protect cultural heritage via artworks, while decreasing disssatisfaction level of the prayers from 45% to 10% in winter months. Additionally, intermittent operation saved 46.9% of energy compared to continuous operating schedule. (C) 2021 Elsevier B.V. All rights reserved.Article Citation - WoS: 70Citation - Scopus: 82A Transdisciplinary Approach on the Energy Efficient Retrofitting of a Historic Building in the Aegean Region of Turkey(Elsevier Ltd., 2015-06-01) Şahin, Cem Doğan; Durmuş Arsan, Zeynep; Tunçoku, Selim Sarp; Broström, Tor; Gökçen Akkurt, Gülden; 02.02. Department of Architecture; 02.01. Department of Conservation and Restoration of Cultural Heritage; 01. Izmir Institute of Technology; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 02. Faculty of ArchitectureAbstract Buildings account for 40% of total energy consumption in the European Union, yet at the same time they have considerable energy saving potentials. Historic buildings should be treated different from contemporary ones when it comes to energy improvements. The specifications which underline historical, sociocultural and architectural values require certain care during realization of energy saving implementations to sustain these values. The purpose of this study is to demonstrate how the energy efficient retrofitting in historic buildings should be managed in a transdisciplinary approach with a case study conducted on the historic building in ̄zmir - Turkey. A detailed building energy simulation tool was used to determine the impacts of energy efficient retrofits. The actual energy consumption of case building was based on the utility bills regarding electricity and heating fuel consumption. Building energy simulation tool was calibrated by comparing the measured and simulated indoor air temperatures and total energy consumptions. The inappropriate retrofits, which contradict to the cultural heritage values, were eliminated with a transdisciplinary approach. Later appropriate retrofits were gathered into three packages to evaluate their effects on the energy consumption. The results show that energy saving of more than 34% can be obtained without damaging the heritage values.Book Part Citation - Scopus: 2Ventilation Strategies for the Preventive Conservation of Manuscripts in the Necip Paşa Library, Izmir, Turkey(Elsevier, 2018) Coşkun, Turgay; Şahin, Cem Doğan; Gülhan, Özcan; Durmuş Arsan, Zeynep; Gökçen Akkurt, Gülden; 02.02. Department of Architecture; 03.10. Department of Mechanical Engineering; 01. Izmir Institute of Technology; 03.06. Department of Energy Systems Engineering; 03. Faculty of Engineering; 02. Faculty of ArchitectureLibraries are specific spaces in which the indoor microclimate should meet rigorous requirements such as the thermal comfort of humans and the conservation of books, manuscripts, and cultural property. An inadequate indoor microclimate (mainly temperature, relative humidity, and their fluctuations) in libraries may cause chemical, biological, and mechanical degradations in paper-based collections. In this chapter, the indoor microclimate of the Necip Paşa Library, the historic library located in Tire-Izmir, Turkey, is discussed from the perspective of the preventive conservation of manuscripts. The library, which has no active heating, cooling, and ventilation system, was modeled with the help of a building energy simulation tool, DesignBuilder. The indoor temperature and relative humidity were monitored throughout 1 year and the model was calibrated with respect to these measurements. To reduce the risks of the manuscripts degrading, ventilation strategies were proposed including natural and mechanical control. The results showed that risks of chemical degradation can be diminished to some extent. © 2018 Elsevier Inc. All rights reserved.