Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/7779
Title: A box–behnken design (Bbd) optimization of the photocatalytic degradation of 2,4-dichlorophenoxyacetic acid (2,4-d) using tio2/h2o2
Authors: Doğdu Okçu, Gamze
Baldan Pakdil, Nazlı
Ökten, Hatice Eser
Yalçuk, Arda
Keywords: Behnken design
Response surface methodology
Photocatalytic degradation
Photocatalysis
Publisher: Desalination Publications
Source: Doğdu Okçu, G., Baldan Pakdil, N., Ökten, H. E., and Yalçuk, A. (2018). A box–behnken design (Bbd) optimization of the photocatalytic degradation of 2,4-dichlorophenoxyacetic acid (2,4-d) using tio2/h2o2. Desalination and Water Treatment, 123, 188-195. doi:10.5004/dwt.2018.22681
Abstract: 2,4-Dichlorophenoxyacetic acid (2,4-D), a chlorinated phenoxy-alkanoic herbicide, is used extensively in agriculture. This work investigates TiO2/H2O2 mediated UV photocatalytic degradation of 2,4-D in a laboratory-scale photoreactor. Three levels of Box–Behnken design technique, combined with response surface methodology (RSM), were used to design the experiments. Two kinds of multivariate experimental design (pH, TiO2, and 2,4-D concentration) and (pH, TiO2, and H2O2 concentrations) were employed to establish two quadratic models (Model 1 and Model 2), showing the functional relationship between degradation rate of 2,4-D and three independent experimental parameters. Model 1 predicted optimum values for pH, TiO2, and 2,4-D concentrations to be 5.7, 1.20 g L−1, and 32 mg L−1, respectively. Model 2 predicted optimum values for pH, TiO2, and initial H2O2 concentrations to be 4.94, 1.34 g L−1, and 161 mg L−1. Degradation rate of 2,4-D approached 78.10% for Model 1 and 83.63% for Model 2. For both models, similar results were obtained through optimizing variables by RSM and using single factorial batch reactor operation. Regression analysis showed good agreement between experimental results and predictive values for Models 1 and 2, with R2 values of 0.9958 and 0.9976, respectively.
URI: https://doi.org/10.5004/dwt.2018.22681
https://hdl.handle.net/11147/7779
ISSN: 1944-3994
1944-3994
1944-3986
Appears in Collections:Environmental Engineering / Çevre Mühendisliği
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Files in This Item:
File Description SizeFormat 
A box-behnken.pdfMakale (Article)2.49 MBAdobe PDFThumbnail
View/Open
Show full item record



CORE Recommender

SCOPUSTM   
Citations

9
checked on Apr 5, 2024

WEB OF SCIENCETM
Citations

6
checked on Mar 27, 2024

Page view(s)

1,684
checked on Apr 22, 2024

Download(s)

740
checked on Apr 22, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.