Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/7760
Title: Development of an optical tyrosinase biosensor (TCA) for detection of “Parathion-Methyl”
Authors: Polatoğlu, İlker
Çakıcıoğlu Özkan, Fehime
Keywords: Adsorption
Organophosphate pesticide
Parathion-methyl
Tyrosinase biosensor
Biosensors
Publisher: Emerald Group Publishing Ltd.
Source: Polatoğlu, İ., and Çakıcıoğlu Özkan, F. (2019). Development of an optical tyrosinase biosensor (TCA) for detection of “Parathion-Methyl”. Sensor Review, 39(4), 604-611. doi:10.1108/SR-10-2018-0242
Abstract: Purpose: This paper aims to present a novel and cost-effective optical biosensor design by simple preparation method for detection of “parathion-methyl,” which is a model pesticide pose to public health and the environment. Design/methodology/approach: The optical enzyme biosensor (TCA) for detection of pesticide “parathion-methyl” was developed on the basis of immobilization of tyrosinase enzyme on chitosan film by adsorption technique. The analytic performance of TCA was investigated by measuring its activity with Ultraviolet (UV) visible spectrophotometer. Findings: Uniform porous network structure and protonated groups of chitosan film provided a microenvironment for tyrosinase immobilization evident from Fourier transform infrared (FTIR) spectroscopy and Atomic Force Microscopy analysis. TCA has a wide linear detection range (0-1.03 µM) with high correlation coefficient and it can detect the parathion-methyl concentration as low as 159 nM by noncompetitive inhibition kinetics. Using the TCA sensor both for ten times and at least 45 days without a significant loss in its activity are the indicators of its good operational and storage stability. Moreover, TCA can be applicable to tap water, providing a promising tool for pesticides detection. Originality/value: This is the first time to use the in situ analytical technique that can improve the performance of optical enzyme sensor provided to control the pesticide residue better with respect to traditional techniques. The effect of organic solvents on the performance of optical enzyme biosensor was investigated. Inhibition kinetic of the solvents rarely encountered in literature was also studied besides the pH and temperature tolerance of the optical biosensor.
URI: https://doi.org/10.1108/SR-10-2018-0242
https://hdl.handle.net/11147/7760
ISSN: 0260-2288
0260-2288
Appears in Collections:Chemical Engineering / Kimya Mühendisliği
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Sürdürülebilir Yeşil Kampüs Koleksiyonu / Sustainable Green Campus Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Files in This Item:
File Description SizeFormat 
10-1108_SR-10-2018-0242.pdfMakale (Article)799.01 kBAdobe PDFThumbnail
View/Open
Show full item record



CORE Recommender

SCOPUSTM   
Citations

4
checked on Apr 5, 2024

WEB OF SCIENCETM
Citations

3
checked on Mar 27, 2024

Page view(s)

232
checked on Apr 22, 2024

Download(s)

366
checked on Apr 22, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.