Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/7212
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorBalantekin, Müjdat-
dc.contributor.authorCoşar, Alper-
dc.date.accessioned2019-07-19T13:07:56Z-
dc.date.available2019-07-19T13:07:56Z-
dc.date.issued2018-12en_US
dc.identifier.citationCoşar, A. (2018). Nonlinear controller design for high speed dynamic atomic force microscope system. Unpublished master's thesis, Izmir Institute of Technology, Izmir, Turkey.en_US
dc.identifier.urihttps://hdl.handle.net/11147/7212-
dc.descriptionThesis (Master)--Izmir Institute of Technology, Electronics and Communication Engineering, Izmir, 2018en_US
dc.descriptionFull text release delayed at author's request until 2019.07.28en_US
dc.descriptionIncludes bibliographical references (leaves: 55-59)en_US
dc.descriptionText in English; Abstract: Turkish and Englishen_US
dc.description.abstractIn this study, the performances of conventionally used PI controller and a nonlinear H∞ controller, are compared in the state-of-the-art High-Speed Dynamic Atomic Force Microscope (HS-AFM). The state-of-the-art HS-AFM system is modeled via MATLAB/ SIMULINK for four different cantilevers, i.e., small high-frequency and regular lowfrequency cantilevers used in air and liquid environments. For the modeled system, PI and H∞ controllers are designed and implemented by using both analytical methods and toolboxes available in MATLAB. Simulations are performed in ideal condition, and under exogenous effects such as noise, disturbance and parametric uncertainty. In ideal condition, achieved maximum frame rate, and the percentage of topography acquisition error with two controllers are calculated for each cantilever. Also, performances of controllers in the system are tested under exogenous effects. It is observed that with the H∞ controller, the topography of the selected sample can be obtained with up to 2 times less acquisition error. It is also observed that PI controller is better in disturbance rejection, but H∞ controller is more robust under the effect of noise. For each cantilever, similar results to the ideal condition is obtained in case of uncertainty. Most distinctive results are obtained with high-frequency cantilevers, as H∞ controller enables a 2 times higher frame rate (14.3 fps) compared to the PI controller (7.1 fps) with the same level of acquisition error in the state-of-the-art HS-AFM operated in liquid environment.en_US
dc.format.extentxi, 59 leavesen_US
dc.language.isoenen_US
dc.publisherIzmir Institute of Technologyen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAtomic force microscopyen_US
dc.subjectPI controlleren_US
dc.titleNonlinear controller design for high speed dynamic atomic force microscope systemen_US
dc.title.alternativeYüksek hızlı dinamik atomik kuvvet mikroskobu sistemi için doğrusal olmayan denetçi tasarımıen_US
dc.typeMaster Thesisen_US
dc.institutionauthorCoşar, Alper-
dc.departmentThesis (Master)--İzmir Institute of Technology, Electrical and Electronics Engineeringen_US
dc.relation.publicationcategoryTezen_US
item.fulltextWith Fulltext-
item.grantfulltextopen-
item.openairetypeMaster Thesis-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.languageiso639-1en-
item.cerifentitytypePublications-
Appears in Collections:Master Degree / Yüksek Lisans Tezleri
Sürdürülebilir Yeşil Kampüs Koleksiyonu / Sustainable Green Campus Collection
Files in This Item:
File Description SizeFormat 
T001839.pdfMasterThesis7.3 MBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

Page view(s)

108
checked on Apr 29, 2024

Download(s)

170
checked on Apr 29, 2024

Google ScholarTM

Check