Title: Analytical solution of micro-/nanoscale convective liquid flows in tubes and slits
Authors: Kalyoncu, Gülce
Barışık, Murat
Keywords: Axial conduction
Kapitza length
Velocity slip coefficient
Viscous dissipation
Heat transfer
Publisher: Springer
Source: Kalyoncu, G., and Barışık, M. (2017). Analytical solution of micro-/nanoscale convective liquid flows in tubes and slits. Microfluidics and Nanofluidics, 21(9). doi:10.1007/s10404-017-1985-5
Abstract: Analytical solutions examining heat transport in micro-/nanoscale liquid flows were developed. Using the energy equation coupled with fully developed velocity, we solved developing temperature profiles with axial conduction and viscous dissipation terms. A comprehensive literature review provided the published range of velocity slip and temperature jump conditions. While molecular simulations and experiments present constant slip and jump values for a specific liquid/surface couple independent of confinement size, non-dimensional forms of these boundary conditions were found appropriate to calculate non-equilibrium as a function of flow height. Although slip and jump conditions are specific for each liquid/surface couple and hard to obtain, we proposed modeling of the slip and jump as a function of the surface wetting, in order to create a general, easy to measure methodology. We further developed possible correlations to calculate jump using the slip value of the corresponding surface and tested in the results. Fully developed Nu showed strong dependence on slip and jump. Heat transfer stopped when slip and jump coefficients became higher than a certain value. Strong variation of Nu in the thermal development length was observed for low slip and jump cases, while an almost constant Nu in the flow direction was found for high slip and jump coefficients. Variation of temperature profiles was found to dominate the heat transfer through the constant temperature surface while surface and liquid temperatures became equal at heat transfer lengths comparable with confinement sizes for no-dissipation cases. In case of non-negligible heat dissipation, viscous heating dominated the Nu value by enhancing the heating while decreasing the heat removal in cooling cases. Implementation of proposed procedure on a micro-channel convection problem from a micro-fluidics application showed the dominant effect of the model defining the slip and jump relationship. Direct use of kinetic gas theory resulted in an increase of Nu by an increase in non-equilibrium, while models developed from published liquid slip and jump values produced an opposite behavior.
URI: http://doi.org/10.1007/s10404-017-1985-5
http://hdl.handle.net/11147/6634
ISSN: 1613-4982
16134990
Appears in Collections:Mechanical Engineering / Makina Mühendisliği
OpenAIRE Collection / OpenAIRE Koleksiyonu
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Files in This Item:
File Description SizeFormat 
6634.pdfMakale2.12 MBAdobe PDFThumbnail
View/Open
Show full item record



CORE Recommender

SCOPUSTM   
Citations

2
checked on Apr 5, 2024

WEB OF SCIENCETM
Citations

2
checked on Mar 16, 2024

Page view(s)

964
checked on Apr 15, 2024

Download(s)

326
checked on Apr 15, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.