DC Field | Value | Language |
---|---|---|
dc.contributor.author | Özyetkin, Mine M. | - |
dc.contributor.author | Nath, Nitendra | - |
dc.contributor.author | Tatlıcıoğlu, Enver | - |
dc.contributor.author | Dawson, Darren M. | - |
dc.date.accessioned | 2017-03-30T07:11:42Z | - |
dc.date.available | 2017-03-30T07:11:42Z | - |
dc.date.issued | 2012 | - |
dc.identifier.citation | Özyetkin, M. M., Nath, N., Tatlıcıoğlu, E., and Dawson, D. M. (2012, October 3-5). A new robust nonlinear control algorithm for the regulation of blood glucose in diabetic patients. Paper presented at the IEEE International Conference on Control Applications, CCA 2012. doi:10.1109/CCA.2012.6402670 | en_US |
dc.identifier.isbn | 9781467345033 | - |
dc.identifier.uri | http://doi.org/10.1109/CCA.2012.6402670 | - |
dc.identifier.uri | http://hdl.handle.net/11147/5177 | - |
dc.description.abstract | Diabetes mellitus is a growing health problem worldwide. Especially, the patients with Type 1 diabetes need strict glycemic control because they have deficiency of insulin production. Today, the aim of the researchers is to develop a fully automated closed loop control system (i. e., artificial pancreas which is capable of continuous glucose sensing and regulating) that replicates the function of pancreatic beta cells. This equipment is supposed to be capable of maintaining normal blood glucose level on a desired level (4-6.2 mmol/L) and taking all factors affecting glucose concentration into account without inducing hypoglycemia and hyperglycemia. In this paper, control of the Bergman minimal mathematical model to regulate blood glucose level is discussed. The control problem is complicated by the fact that the model is considered to be uncertain. Furthermore, only the glucose level is assumed to be available for control development and other states such as insulin concentration and plasma insulin concentration are assumed to be unavailable for measurement. A novel robust controller is proposed that guarantees practical tracking of a desired glucose concentration. © 2012 IEEE. | en_US |
dc.description.sponsorship | TUBITAK; Ministry of Science, Industry and Technology of Turkey (grant 1402.TGSD.2012) | en_US |
dc.language.iso | en | en_US |
dc.publisher | Institute of Electrical and Electronics Engineers Inc. | en_US |
dc.relation.ispartof | IEEE International Conference on Control Applications, CCA 2012 | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Glucose | en_US |
dc.subject | Robust control | en_US |
dc.subject | Diabetic patient | en_US |
dc.subject | Insulin concentrations | en_US |
dc.subject | Pancreatic beta cells | en_US |
dc.title | A new robust nonlinear control algorithm for the regulation of blood glucose in diabetic patients | en_US |
dc.type | Conference Object | en_US |
dc.authorid | TR123720 | en_US |
dc.institutionauthor | Tatlıcıoğlu, Enver | - |
dc.department | İzmir Institute of Technology. Electrical and Electronics Engineering | en_US |
dc.identifier.startpage | 1057 | en_US |
dc.identifier.endpage | 1061 | en_US |
dc.identifier.wos | WOS:000320336200152 | en_US |
dc.identifier.scopus | 2-s2.0-84873148269 | en_US |
dc.relation.publicationcategory | Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı | en_US |
dc.identifier.doi | 10.1109/CCA.2012.6402670 | - |
dc.relation.doi | 10.1109/CCA.2012.6402670 | en_US |
dc.coverage.doi | 10.1109/CCA.2012.6402670 | en_US |
dc.identifier.wosquality | N/A | - |
dc.identifier.scopusquality | N/A | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.languageiso639-1 | en | - |
item.cerifentitytype | Publications | - |
item.grantfulltext | open | - |
item.openairetype | Conference Object | - |
item.fulltext | With Fulltext | - |
crisitem.author.dept | 03.05. Department of Electrical and Electronics Engineering | - |
Appears in Collections: | Electrical - Electronic Engineering / Elektrik - Elektronik Mühendisliği Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
SCOPUSTM
Citations
3
checked on Oct 25, 2024
WEB OF SCIENCETM
Citations
2
checked on Oct 5, 2024
Page view(s)
210
checked on Oct 28, 2024
Download(s)
316
checked on Oct 28, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.