Title: Performance of the CMS cathode strip chambers with cosmic rays
Authors: Demir, Durmuş Ali
CMS Collaboration
Keywords: Large detector systems
Particle tracking detectors
Gaseous detectors
Cathode Strip Chambers
Compact Muon Solenoid
Cosmic Run At Four Tesla (CRAFT)
Large Hadron Collider (LHC)
Publisher: IOP Publishing Ltd.
Source: Chatrchyan, S., Khachatryan, V., Sirunyan, A. M., Adam. W., Arnold, B., ...CMS Collaboration (2010). Performance of the CMS cathode strip chambers with cosmic rays. Journal of Instrumentation, 5(3). doi:10.1088/1748-0221/5/03/T03018
Abstract: The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47μm to 243μm. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns. © 2010 IOP Publishing Ltd and SISSA.
URI: http://doi.org/10.1088/1748-0221/5/03/T03018
http://hdl.handle.net/11147/2580
ISSN: 1748-0221
Appears in Collections:Physics / Fizik
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Files in This Item:
File Description SizeFormat 
2580.pdfMakale1.33 MBAdobe PDFThumbnail
View/Open
Show full item record



CORE Recommender

SCOPUSTM   
Citations

35
checked on Mar 22, 2024

WEB OF SCIENCETM
Citations

34
checked on Mar 27, 2024

Page view(s)

136
checked on Mar 25, 2024

Download(s)

202
checked on Mar 25, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.