Show simple item record

dc.contributor.authorTuyan, Murat
dc.contributor.authorAhari, Reza Saleh
dc.contributor.authorErdem, Tahir Kemal
dc.contributor.authorCakir, Ozge Andic
dc.contributor.authorRamyar, Kambiz
dc.date.accessioned2020-07-25T22:07:51Z
dc.date.available2020-07-25T22:07:51Z
dc.date.issued2018
dc.identifier.issn0950-0618
dc.identifier.issn1879-0526
dc.identifier.urihttps://doi.org/10.1016/j.conbuildmat.2018.04.046
dc.identifier.urihttps://hdl.handle.net/11147/9222
dc.descriptionTuyan, Murat/0000-0003-2149-8437; saleha ahari, reza/0000-0003-3471-1727en_US
dc.descriptionWOS: 000432645200020en_US
dc.description.abstractIn this experimental study, the influence of thixotropy determined by different test methods on the formwork pressure of self-consolidating concrete (SCC) with varying compositions was investigated. In order to determine the effect of water/binder (w/b) ratio, slump flow diameter and coarse aggregate/total aggregate (CA/TA) ratio on thixotropy and formwork pressure of SCC, fifteen concrete mixtures were prepared. Four different test methods i.e., "structural break-down area" (SBDA), "break-down percentage" (BDP), "drop in apparent viscosity" (DAV) and "yield value at rest" (YVR) were performed to determine the thixotropy of the SCC mixtures. Test results showed that the SBDA, DAV and YVR methods were more appropriate to evaluate the thixotropy of SCC than the BDP method. A strong correlation between thixotropy and formwork pressure was found using SBDA, DAV and YVR methods in SCC mixtures having low w/b ratio. There was a strong relationship between thixotropy determined by SBDA, BDP and DAV methods and formwork pressure in low slump flow SCC mixtures, while thixotropy determined by the YVR method showed good correlation with the formwork pressure in SCC mixtures having high slump flow values. Finally, new models were developed to estimate the formwork pressure of all kinds of mixtures as a function of thixotropy and time. The models were found to be successful for each of the thixotropy measurement method. (C) 2018 Elsevier Ltd. All rights reserved.en_US
dc.language.isoengen_US
dc.publisherElsevier Sci Ltden_US
dc.relation.isversionof10.1016/j.conbuildmat.2018.04.046en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectSelf-consolidating concreteen_US
dc.subjectThixotropy methodsen_US
dc.subjectFormwork pressureen_US
dc.titleInfluence of thixotropy determined by different test methods on formwork pressure of self-consolidating concreteen_US
dc.typearticleen_US
dc.relation.journalConstruction And Building Materialsen_US
dc.contributor.departmentIzmir Institute of Technologyen_US
dc.identifier.volume173en_US
dc.identifier.startpage189en_US
dc.identifier.endpage200en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.cont.department-temp[Tuyan, Murat; Cakir, Ozge Andic; Ramyar, Kambiz] Ege Univ, Dept Civil Engn, Bornova, Turkey; [Ahari, Reza Saleh] Islamic Azad Univ, Dept Civil Engn, Tabriz Branch, Tabriz, Iran; [Erdem, Tahir Kemal] Izmir Inst Technol, Dept Civil Engn, Urla Izmir, Turkeyen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record