Show simple item record

dc.contributor.authorÖner, Merve
dc.contributor.authorKazanasmaz, Zehra Tuğçe
dc.date.accessioned2019-11-04T10:28:05Z
dc.date.available2019-11-04T10:28:05Z
dc.date.issued2019en_US
dc.identifier.citationM. Öner, T. Kazanasmaz (2019). Illuminance and luminance based ratios in the scope of performance testing of a light shelf-reflective louver system in a library reading room. Light and Engineering, 27(3), 39-46. doi:10.33383/2018-067.en_US
dc.identifier.issn0236-2945
dc.identifier.urihttps://doi.org/10.33383/2018-067
dc.identifier.urihttps://hdl.handle.net/11147/7326
dc.description.abstractUncontrolled daylight brings visual and thermal problems that may result in negative interactions with user comfort, productivity, well-being, and human health. Library spaces, in which reading, writing, and computer task activities are performed, need to be well designed in terms of daylight performance to enhance user satisfaction. The focus of this study is to make a performance test of a light shelf-reflective louver system to improve the visual performance conditions of a library reading room. First, the instrumental monitoring of existing daylighting conditions was performed. Second, Relux model was prepared to evaluate luminance patterns and illuminance distribution. Third, a new light shelf-reflective louver system was proposed based on the insufficiencies of the simulation results. The performance of the new system was found highly satisfactory based on the findings of enhanced luminance patterns and uniformity ratios especially at the points near the windows.en_US
dc.language.isoengen_US
dc.publisherLight and Engineeringen_US
dc.relation.isversionof10.33383/2018-067en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rightsAttribution-NonCommercial 3.0 United States*
dc.rights.urihttp://creativecommons.org/licenses/by-nc/3.0/us/*
dc.subjectDaylightingen_US
dc.subjectVisual performanceen_US
dc.subjectLibraryen_US
dc.subjectIlluminanceen_US
dc.subjectLuminanceen_US
dc.subjectLight shelfen_US
dc.subjectReflective louveren_US
dc.titleIlluminance and luminance based ratios in the scope of performance testing of a light shelf-reflective louver system in a library reading roomen_US
dc.typearticleen_US
dc.contributor.authorID0000-0001-7844-1373en_US
dc.contributor.iztechauthorÖner, Merve
dc.contributor.iztechauthorKazanasmaz, Zehra Tuğçe
dc.relation.journalLight and Engineeringen_US
dc.contributor.departmentİzmir Institute of Technology. Architectureen_US
dc.identifier.volume27en_US
dc.identifier.issue3en_US
dc.identifier.startpage39en_US
dc.identifier.endpage46en_US
dc.identifier.wos
dc.identifier.scopusSCOPUS:2-s2.0-85070945500
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess