Break-even analysis and size optimization of a PV/wind hybrid energy conversion system with battery storage - A case study

Thumbnail

View/Open

Makale (1.130Mb)

Access

info:eu-repo/semantics/openAccess

Date

2009-07

Author

Ekren, Orhan
Yetkin Ekren, Banu
Özerdem, Barış

Metadata

Show full item record

Citation

Ekren, O., Yetkin Ekren, B., and Özerdem, B. (2009). Break-even analysis and size optimization of a PV/wind hybrid energy conversion system with battery storage - A case study. Applied Energy, 86(7-8), 1043-1054. doi:10.1016/j.apenergy.2008.09.024

Abstract

This paper aims to show an optimum sizing procedure of autonomous PV/wind hybrid energy system with battery storage and a break-even analysis of this system and extension of transmission line. We use net present value (NPV) method for the comparison of autonomous hybrid energy system and extension of transmission line cases. The case study is completed for the satisfaction of the electricity consumption of global system for mobile communication base station (GSM) at Izmir Institute of Technology Campus Area, Urla, Izmir, Turkey. First, we optimize the PV/wind energy system using response surface methodology (RSM) which is a collection of statistical and mathematical methods relying on optimization of response surface with design parameters. As a result of RSM, the optimum PV area, wind turbine rotor swept area, and battery capacity are obtained as 3.95 m2, 29.4 m2, 31.92 kW h, respectively. These results led to $37,033.9 hybrid energy system cost. Second, break-even analysis is done to be able to decide the optimum distance where the hybrid energy system is more economical than the extension of the transmission line. The result shows that, if the distance between national electricity network and the GSM base station location where the hybrid energy system is assumed to be installed is at a distance more than 4817 m, the installation of hybrid energy system is more economical than the electricity network.

Source

Applied Energy

Volume

86

Issue

7-8

URI

http://dx.doi.org/10.1016/j.apenergy.2008.09.024
http://hdl.handle.net/11147/2534

Collections

  • Mechanical Engineering / Makina Mühendisliği [513]
  • Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection [4673]
  • WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection [4803]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Policy | Guide | Contact |

DSpace@IZTECH

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


| Policy | | Guide | Library | idealdspace University | OAI-PMH |

IYTE, İzmir, Turkey
If you find any errors in content, please contact:

Creative Commons License
idealdspace University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@IZTECH is member of:



DSpace Release 6.2